7.1 Introduction

This chapter illustrates some of the methods used for evaluating the physical and psychophysical performances of digital detectors for imaging in mammography. Objective and subjective measurements by means of human observers and automatic methods can be achieved to better characterize the performance of digital systems. Some results from commercial units are also presented.

To assess the image quality of the various systems, spatial resolution and noise properties can be evaluated using metrics such as the modulation transfer function (MTF), noise power spectra (NPS), noise-equivalent quanta (NEQ), and detective quantum efficiency (DQE). While the image quality of different systems can be characterized by using these objective measures, medical diagnosis also involves perception of the observer. Since an image is, by definition, a means for visually representing the clinical information captured by the equipment, at some stage quality must be based on the judgment of a human observer. A more direct image-based method of evaluating overall system performance is by using contrast-detail (CD) phantoms. These phantoms contain test objects of different size and contrast and are traditionally used to determine the boundary between visible and invisible objects represented by the imaging system. An issue with this type of experiment is that subjective observation can often result in relatively high inter- and intra-observer variability.

A high-quality image is of major importance to assure an accurate diagnosis, and this is generally determined by three primary physical image-quality parameters: contrast, spatial resolution, and noise. These quality parameters can be evaluated by objective image-quality measurements such as signal-to-noise ratio (SNR), MTF, and NPS. Together they form a basis for the description of image quality that encompasses the three primary physical image-quality parameters. These factors contribute to the measurement of DQE, which has been well established as the most suitable parameter for describing the imaging performance of an x-ray digital imaging device. DQE is the measurement of the combined effects of the noise and contrast performance of an imaging system, expressed as a function of object detail.

© 2012 Society of Photo-Optical Instrumentation Engineers (SPIE)

Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.