You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
4 November 1981System For Automated Real-Time Generation Of Higher Order Energy Subtraction Images In Digital Fluoroscopy
When energy subtraction methods are employed in digital radiography it is necessary to combine the initial images in a weighted fashion. This paper discusses the instrumentation developed to automatically generate up to quadratic order combinations of x-ray images at realtime video rates in energy subtraction digital fluorography. Although the energy mode used is three-beam K-edge subtraction, the same instrumentation can also be used for dual beam imaging. The method is implemented by first acquiring logarithmically amplified digital fluorographic images of a calibration phantom with each of three spectrally different x-ray beams. The distribution of iodinated contrast material in the phantom is presumed known and the phantom thicknesses cover the range expected to be encountered clinically. Next, individual pixel values from the images are automatically fed to a PDP 11/10 computer where the weighting coefficients are calculated by least squares. The optimum coefficients are next loaded from the computer into a hardware multiplier network capable of combination of 256 x 256 pixel images at realtime video rates. Once loaded with the fitted coefficients the network is then calibrated and ready to generate energy sub-traction images of arbitrary objects. The complexity of the image combination may range from linear to full quadratic combination of differences of the three initial images. The emphasis of this paper is a discussion of the closed form iodine specific fit used to determine the coefficients and the instrumentation aspects of the system: design of the computer interface and design and operation of the multiplier network. Sample experimental results are presented.
The alert did not successfully save. Please try again later.
S. J. Riederer, D. L. Ergun, R. A. Kruger, C. G. Shaw, C. A. Mistretta, "System For Automated Real-Time Generation Of Higher Order Energy Subtraction Images In Digital Fluoroscopy," Proc. SPIE 0314, Digital Radiography, (4 November 1981); https://doi.org/10.1117/12.933048