Paper
14 January 1986 Myocardial Dose Response To Argon Laser Irradiation In Saline And Blood With Ultramicroscopical Analysis Of Myocardial Debris
Giora Ben-Shachar, Dennis E. Morse, Mark C. Sivakoff, Thomas A. Riemenschneider
Author Affiliations +
Abstract
Fresh myocardial segments from fetal and adult sheep, and from newborn and adult pigs were exposed to continuous mode argon laser irradiation in saline medium. Additionally, myocardial segments from newborn pigs were exposed to laser irradiation in fresh, heparin-ized blood medium. The irradiation distance from the tip of the quartz fiber to the tissue varied between contact and 20 mm, and power output at the fiber tip varied between 1 and 8 watts. Exposure time was kept constant at 2 seconds. Tissue debris was also processed for study by scanning and transmission electron microscopy. There was no difference in myocardial tissue response between sheep and pigs, nor was there a difference in response between young and adult animals. In both saline and blood media, there was a sharp decrease in burn depth with increasing irradiation distance. With increasing irradiation distances in saline medium, burn diameter increased initially and then plateaued; while with increasing irradiation distance in blood medium, the burn diameter decreased sharply. When the fiber tip was in contact with the tissue, the diameter of burn was greater in blood than saline, while the depth of burn was similar. Filtration of the tissue bath demonstrated particles as large as 3 mm in length which were composed of deformed and coagulated whole tissue segments. Electron and scanning micrography of the bath media identified intracellular components and fragments of burst cells. In conclusion, we have found no difference in adult vs. newborn, or sheep vs. porcine myocardial response to fiberoptic argon laser irradiation. The most critical factors affecting width and depth of burn were the distance of the fiber tip from the tissue, and the medium in which the tissue was bathed. Of particular clinical importance was the fact that the burn width and depth drastically decreased when blood was present between the laser fiber and the tissue.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Giora Ben-Shachar, Dennis E. Morse, Mark C. Sivakoff, and Thomas A. Riemenschneider "Myocardial Dose Response To Argon Laser Irradiation In Saline And Blood With Ultramicroscopical Analysis Of Myocardial Debris", Proc. SPIE 0576, Optical Fibers in Medicine and Biology I, (14 January 1986); https://doi.org/10.1117/12.950734
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Laser tissue interaction

Blood

Laser irradiation

Argon ion lasers

Fetus

Heart

RELATED CONTENT

Laser therapy in cardiovascular disease
Proceedings of SPIE (February 23 2009)
Fiber design for interstitial laser treatment
Proceedings of SPIE (July 01 1991)
Laser Angioplasty With Contact Sapphire Probe
Proceedings of SPIE (April 01 1987)

Back to Top