3 June 1987 The Scatterometer For DIRBE
John F Bolton
Author Affiliations +
Abstract
A technique for monitoring the degradation in performance of an infrared instrument caused by contamination of the primary mirror is needed. A scatterometer, measuring the light from an off-axis source transmitted through the instrument, is proposed. The design and analysis of this device is described.
© (1987) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John F Bolton "The Scatterometer For DIRBE", Proc. SPIE 0675, Stray Radiation V, (3 June 1987); https://doi.org/10.1117/12.939496