You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
9 March 2017Development of a novel method based on a photon counting technique with the aim of precise material identification in clinical x-ray diagnosis
A photon counting system has the ability of energy discrimination, therefore obtaining new information using X-rays for material identification is an expected goal to achieve precise diagnosis. The aim of our study is to propose a novel method for material identification based on a photon counting technique. First, X-ray spectra at 40-60 kV were constructed using a published database. Second, X-ray spectra penetrating different materials having atomic numbers from 5-13 were calculated. These spectra were divided into two energy regions, then linear attenuation factors concerning these regions were obtained. In addition, in order to accomplish highly accurate material identification, correction of beam hardening effects based on soft-tissue was applied to each linear attenuation factor. Then, using the linear attenuation factors, a normalized linear attenuation coefficient was derived. Finally, an effective atomic number was determined using the theoretical relationship between the normalized linear attenuation coefficient and atomic number. In order to demonstrate our method, four different phantoms (acrylic, soft-tissue equivalent, bone equivalent, and aluminum) were measured using a single-probe-type CdTe detector under the assumption that the response of the single-probe-type CdTe detector is equal to the response of one pixel of a multi-pixel-type photon counting detector. Each of these phantoms can be completely separated using our method. Furthermore, we evaluated an adoptive limit of beam hardening correction. We found that the adoptive limit depends on the mass thickness and atomic number. Our vision is to realize highly accurate identification for material with narrow range in atomic number.
The alert did not successfully save. Please try again later.
Natsumi Kimoto, Hiroaki Hayashi, Takashi Asahara, Yuki Kanazawa, Tsutomu Yamakawa, Shuichiro Yamamoto, Masashi Yamasaki, Masahiro Okada, "Development of a novel method based on a photon counting technique with the aim of precise material identification in clinical x-ray diagnosis," Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging, 1013239 (9 March 2017); https://doi.org/10.1117/12.2253564