In this paper we present the basics of SCIR & DCIR architecture and the main differences between them. In addition, we will present the results from a thorough study conducted for the purpose of learning about the added value of the additional data available from the second spectral band. Here we consider the two CO2 bands of 4-5 micron and of 2.5-3 micron band as well as off peak band (guard). The findings of this study refer also to Missile warning systems (MWS) efficacy, in terms of operational value. We also present a new approach for tunable filter to such sensor. |
ACCESS THE FULL ARTICLE
No SPIE Account? Create one
Flame detectors
Infrared detectors
Carbon dioxide
Infrared detection
Medium wave
Missiles
Optical filters