Paper
24 October 2017 Computational diffraction tomographic microscopy with transport of intensity equation using a light-emitting diode array
Author Affiliations +
Proceedings Volume 10458, AOPC 2017: 3D Measurement Technology for Intelligent Manufacturing; 104580O (2017) https://doi.org/10.1117/12.2283390
Event: Applied Optics and Photonics China (AOPC2017), 2017, Beijing, China
Abstract
Optical diffraction tomography (ODT) is an effective label-free technique for quantitatively refractive index imaging, which enables long-term monitoring of the internal three-dimensional (3D) structures and molecular composition of biological cells with minimal perturbation. However, existing optical tomographic methods generally rely on interferometric configuration for phase measurement and sophisticated mechanical systems for sample rotation or beam scanning. Thereby, the measurement is suspect to phase error coming from the coherent speckle, environmental vibrations, and mechanical error during data acquisition process. To overcome these limitations, we present a new ODT technique based on non-interferometric phase retrieval and programmable illumination emitting from a light-emitting diode (LED) array. The experimental system is built based on a traditional bright field microscope, with the light source replaced by a programmable LED array, which provides angle-variable quasi-monochromatic illumination with an angular coverage of ±37 degrees in both x and y directions (corresponding to an illumination numerical aperture of ∼ 0.6). Transport of intensity equation (TIE) is utilized to recover the phase at different illumination angles, and the refractive index distribution is reconstructed based on the ODT framework under first Rytov approximation. The missing-cone problem in ODT is addressed by using the iterative non-negative constraint algorithm, and the misalignment of the LED array is further numerically corrected to improve the accuracy of refractive index quantification. Experiments on polystyrene beads and thick biological specimens show that the proposed approach allows accurate refractive index reconstruction while greatly reduced the system complexity and environmental sensitivity compared to conventional interferometric ODT approaches.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jiaji Li, Qian Chen, Jialin Zhang, and Chao Zuo "Computational diffraction tomographic microscopy with transport of intensity equation using a light-emitting diode array", Proc. SPIE 10458, AOPC 2017: 3D Measurement Technology for Intelligent Manufacturing, 104580O (24 October 2017); https://doi.org/10.1117/12.2283390
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microscopy

Tomography

Diffraction

Image restoration

Light emitting diodes

Medical imaging

Phase retrieval

Back to Top