Abstract
There are many advantages to employing fiber optics for high capacity satellite communication. However, optical cables can be susceptible to high radiation, temperature extremes and vacuum environment. Any hardware used in these systems must be rugged, durable and immune to the detrimental effects of the aforementioned conditions.

Standard COTS optical fiber will darken when exposed to high levels of radiation limiting the effectiveness of the communications system. Of particular concern to satellites in GEO are energetic electrons, bursts of heavy particles due to solar storms which can cause total dose and single event effects (SEE). Conventional fiber optic cables have several issues performing in high radiation environments. Linden has patented and developed a novel cable using an extruded layer of Liquid Crystal Polymer (LCP) applied to commercially available fiber. Total dose effects are minimized by shielding with Liquid Crystal Polymer jacketing. It is a simple, inexpensive way to increase the radiation shielding and mechanical performance of cables in satellites while concomitantly providing hermeticity and thus increased fatigue factor for optical glass.

• LCPs exposed to 5000 Mrad dose of gamma rays retain in excess of 90% of their mechanical properties.

• LCPs exposed to 1 Mrad radiation dose with energetic protons retain almost 100% of their mechanical strength. Tensile modulus increases with exposure to the radiation.

• Weight for weight the proton absorbing power of LCP is 25% better than that of aluminum.

We will present experimental data on radhard optical patchcords.

1.

Introduction

There are many advantages to employing fiber optics for high capacity satellite communications; their reduced physical size, reduced weight, lower power consumption, greater bandwidth, better immunity from interference, and ability to effectively communicate with a higher number of satellites in any given orbital slot. However, optical cables can be susceptible to the rigors of the space environment – such as radiation, vibration, temperature extremes and vacuum environment. Linden has developed a novel radiation resistance, non-kink, optical cable (RAVNOC) that uses an extruded layer of Liquid Crystal Polymer (LCP) applied to commercially available radhard fiber. This cable has been tested successfully against rigorous European Space Agency – ESCC Basic Specification No. 2263010. This paper will describe construction of Linden’s RAVNOC, the properties of LCP properties and test results for RAVNOC.

2.

Construction of Radiation Resistant, Non-kink, Optical Cable (RAVNOC)

Linden’s radhard optical cable uses a commercially available polyimide buffered radhard fiber, surrounded by extruded layers of liquid crystal polymer (LCP) and FEP as shown in Figure 1.

Figure 1.

Design of RAVNOC

00047_PSISDG10564_105641I_page_3_1.jpg

2.1.

Choice of RadHard Optical Fiber

Most vendors that offer radhard optical fibers do not disclose their fiber designs but is it likely that they are mostly pure silica core fibers expect for the fluorine doped core fiber which is available from Fujikura (Aikawa, 2008). A group at CERN, European Organization for Nuclear Research, Geneva, has performed a detailed radiation resistance comparison of several different commercially available optical fibers (De Jonge, 2008) the results of which are in Figure 2 and Fujikura’s results are in Figure 3. General conclusions are as follows:

  • Fluorine doped fibers from Fujikura Ltd show the lowest Radiation Induced Attenuation (RIA) < 2 dB/km at 1310 and 1550 nm after a total dose of 1 Mrad.

  • Conventional Germanium doped fibers show RIA between 10 and 100 dB/km for same dose.

  • Pure silica core fibers are available from several vendors and their RIA is in the range of 10 dB/km.

  • RIA in Co-60 and HEP radiation fields are comparable.

Figure 2.

Radiation Induced Attenuation in Optical Fiber (1 gray = 100 rad)((De Jonge, 2008)

00047_PSISDG10564_105641I_page_4_1.jpg

Figure 3.

Radiation Induced Attenuation (RIA) in pure silica core (A) and fluorine doped core (C) optical fibers (Aikawa, 2008).

00047_PSISDG10564_105641I_page_4_2.jpg

3.

Liquid Crystal Polymer (LCP) Properties

3.1.

Effect of Gamma Rays on LCP

The effect of gamma radiation on A950 LCP is documented by Ticona Corp and is reproduced in Table 1. Clearly LCP will survive typical gamma radiation levels in space.

Table 1.

Cobalt 60 gamma radiation, Vectra A950 LCP (Percentage retention of properties.) Source: Ticona technical literature

Radiation Dose250 Mrads1000 Mrads2500 Mrads5000 Mrads
Tensile Strength97959595
Tensile Modulus100100106106
Break Elongation81817979
Flexure Strength101102102102
Flexture Modulus10810811694

3.2.

Mechanical Strength of Optical Cables after Irradiation

Linden Photonics, in conjunction with Auburn University and Gray Research, tested optical patchcords with LCP jacketing to test for strength before and after exposure. A Co-60 source was used and the samples were subjected to radiation at room temperature. The dose rate was measured with a calibrated dosimeter the day before testing began. Dose rate was measured at 81 rad(Si)/sec. The sample temperature was estimated to increase by ~10K above room temperature during exposure due to gamma-ray heating. Exposure levels were 105, 262, 525, and 1050 krad(Si).

Mechanical measurements made included tensile strength and flexibility. We performed flex testing on samples to determine when the LCP layer would break and when the outside jacket layer would break. This was performed on a flex tester designed to SAE standard AS5382. As is shown in Figure 4, Figure 5, and Figure 6, there was no demonstrable decrease in tensile strength or flexibility with the increase in exposure.

Figure 4.

Tensile Strength vs. Dose

00047_PSISDG10564_105641I_page_5_1.jpg

Figure 5.

Flex Cycles till LCP Breakage vs. Dose

00047_PSISDG10564_105641I_page_5_2.jpg

Figure 6.

Flex Cycles till Outer Jacket Breakage vs. Dose

00047_PSISDG10564_105641I_page_6_1.jpg

3.3.

Range of Energetic Protons in LCPs.

We used programs developed by Dr. Barney Doyle at Sandia National Laboratory to calculate range of high energy protons in various materials. Results are summarized in Table 2.

Table 2.

Range in Vectra LCP, copper and aluminum, as a function of proton energy.

Proton Energy, MeVFluence in MEO (#/cm2/day, Barth, 1997)Range in Vectra LCP (μm)Range in copper (μm)Range in aluminum (μm)Range in PET (μm)
10109164046811271574
51010468   
1101229   
0.110131   

Obviously it is the highest energy protons that have the largest range. Note that the LCP has to be thicker by a factor of 3 than copper to stop 10 MeV protons. However, the density of LCP is much less. Hence a figure of merit, determined by the product of density and range, can be used to determine the cost effectiveness of shielding. Table 1 shows the figure of merit for various materials. LCP figure of merit is better (lower) than aluminum.

Table 3.

Figure of merit comparison of shielding strength.

MaterialRange of 10 MeV protons (cm)Density (gm/cm3)Figure of merit (gm/cm2)
Vectra LCP0.1641.40.23
Copper0.04688.960.42
Aluminum0.11272.70.30

3.4.

Moisture Barrier Properties of LCP Coated Optical Cable

It is one of the primary functions of the optical fiber coating that it prevents the ingress of water vapor, as the strength of the optical fiber deteriorates rapidly in the presence of moisture due to stress corrosion. All polymers are permeable to water to some degree. The permeability is given by the product of the moisture diffusion coefficient D, and the solubility S, and is defined as the mass of water transmitted per unit area per unit time per unit of pressure for a given thickness of the polymer. LCPs, because of their rigid crystalline molecular orientation, exhibit the lowest levels of moisture permeability of any polymer. The relative permeability of Vectra A950 LCP and a variety of other commonly used polymers is shown in Figure 7. Tensile strength retention of silica fiber protected by hermetic carbon coating and LCP coating is compared in Figure 8.

Figure 7.

Permeability of various polymer films (25 μm thickness)

00047_PSISDG10564_105641I_page_7_1.jpg

Figure 8.

Moisture aging of carbon and LCP coated silica optical fiber

00047_PSISDG10564_105641I_page_7_2.jpg

3.5.

Strength and Modulus

The modulus, strength and other mechanical properties of LCPs are dependent upon the degree of molecular alignment, which in turn is influenced by the manufacturing process. Table 4 shows the elastic modulus and ultimate tensile strength (UTS) of several filled and unfilled bulk materials produced by Ticona, under the trade name Vectra.

Table 4.

Modulus and UTS of Vectra LCPs (Bulk)

MaterialTypeModulus Kpsi (Gpa)UTS Kpsi (Mpa)
A950Unfilled1590 (10.6)27.3 (182)
A23030% Carbon Filled3407 (23.5)18.8 (130)
B13030% Glass Filled3190 (22)30 (205)
B23030% Carbon Filled4611 (31.8)29 (200)

The values given in the table are derived from measurements performed on bulk samples which have been produced by injection molding. In previous work with extruded LCP coatings, we have demonstrated that thinly extruded LCP can exhibit tensile modulus and strength many times greater than the values given above.

4.

Results of Qualification Testing

We conducted qualification testing as per European Space Components Coordination (ESCC) Specification No. 2263010 for fiber connector sets. We tested 50 μm, graded index multimode fiber patchcords with AVIM/APC connectors on one end and FC/UPC connectors on the other (Figure 9).

Figure 9.

Test samples used for qualification

00047_PSISDG10564_105641I_page_8_1.jpg

4.1.

Optical Insertion Loss (IL)

Insertion loss (IL) of the connectors is the first critical test and the requirement is for IL <0.2 dB where IL is defined as loss through two mated AVIM/APC connectors. This is a stringent requirement. Typical tolerances in connector sleeves coupled with fiber dimension tolerances results in IL< 0.4 dB. See, for example, Telcordia Technologies Generic Requirements, GR-326-CORE. Of 30 mated AVIM/APC connector pairs tested only 17 passed this test. On the other hand if IL requirement is relaxed to 0.4 dB, 29 pairs would have passed. Inherent tolerances in connector parts and in the polishing process such as undercut, radius of curvature (ROC) and dome offset (Apex) imply that the only way to get IL< 0.2 dB is to down-select from finished patchcords which doubles the cost.

The effect of connector end-face geometry is summarized in Table 1. It appears that the most significant difference in failed and passing assemblies is in the undercut. Because of the soft metal insert used in AVIM connector ferrules vs. a standard ceramic ferrule the fiber tends to protrude.

Table 5.

Connector IL dependence on end-face geometry

 Ratio of st. dev./average
ROCUndercut/ProtrusionApex
All assemblies0.100.180.41
Passing Assemblies0.080.150.40
Failed Assemblies0.140.250.37

4.2.

Other qualification tests

Other tests performed and a summary of results are listed in Table 6

Table 6.

Qualification tests performed as per (ESCC) Specification No. 2263010

TestNo. of patchcords testedResults of test
High temp stress test (5 hr. at 1200 C)2Passed
Low temp stress test (5 hr. at -700 C)2Passed
Impact test2Passed
Torsion test2Passed
Side static load2Passed
Tension test2Passed up to tension of 25 N
Strength of coupling mechanism1Passed
Mechanical shock2Passes
Vibration test2Passed
Thermal cycle64/6 passed
Rapid change of temperature2Passed
Salt mist2Passed
Rapid depressurization2Passed
Mating durability over 500 mating cycles2Failed because threads on mating adapter wore out
Temperature life42/3 passed

5.

Discussion of selected tests

For most of the tests Insertion Loss (IL) must be < 0.2 dB and Return Loss (RL) must be > 40 dB before and after the test, and change in transmittance (CIT) must not exceed 0.3 dB during the test.

5.1.

High and low temperature stress test

Cables are tested at temperature extremes of 1200 C and -700 C for 5 hours. Of two assemblies tested one assembly (S2 made with connectors C3 and C4) failed CIT during 5 hr. soak at 1100 C and 1200 C. Connector endface details for the two tested assemblies are shown in Table 1.

Table 7.

Details of assemblies tested for temperature stress

AssemblyPatchcordAssemblyROCUndercutDome Offset
5-12 mm< 100 nm< 50 μm
S1-passedC111.0641379.82
C213.8222240.73
S2 - failedC312.87242103.82
C414.20237133.32

Comparison shows that the failed assembly had significantly higher dome offset which may, therefore, be a critical element in achieving better temperature performance.

5.2.

Temperature life test therefore, be a critical element in achieving better temperature performance.

Four assemblies are exposed to a temperature extreme of 85°C for 2000 hours. One assembly failed CIT. Connector analysis is in 0.

Table 8.

Assemblies tested for temperature cycle

AssemblyPatchcordAssemblyConnectorTypeROCUndercut/ProtrusionDome Offset
5-12 mm< 100 nm< 50 μm
S20 - passedC39AVIM/APC14.1925551.13
C40AVIM/APC10.9942179.61
S21 - failed CITC53AVIM/APC11.4340269.93
C54AVIM/APC12.7134471.00
S22 - passedC43AVIM/APC11.9444850.58
C45AVIM/APC13.3421859.29
S23 - passedC55AVIM/APC11.5738033.57
C56AVIM/APC10.2344069.89

Again we see that, while all assemblies had fairly high protrusion, the failed assembly had high dome offset for both connectors. It appears that dome offset may be the parameter that needs to be improved or selected against to improve performance on temperature related tests.

5.3.

Thermal Cycle

This may be the most stringent temperature test. Six assemblies are cycled from -400 C to 850 C for a total of 100 cycles. Dwell time at temperature extremes is 0.75 hr. CIT as a function of time is shown in Figure 10. Two out of six assemblies failed CIT. Note that connector pairs that failed seem to do so within the first 10 cycles. Also one of the failed samples shows CIT oscillation in sync with the temperature cycles. This is indicative of pistoning of the fiber in the ferrule resulting in a temperature dependent Fabry Perot effect. This can be improved by lower protrusion and higher temperature curing of the epoxy.

Figure 10.

Change in Transmittance vs Climatic Data for Thermal Cycle

00047_PSISDG10564_105641I_page_10_1.jpg

5.4.

Radiation testing

This test was performed independently of the ESCC Specification No. 2263010 testing by one of our customers. They tested patchcords to 20 MRad. The Relative Optical Power [dB] was measured before irradiation and after 5 MRad, 10 MRad, and 20 Mrad as intermediate measurement points. Then the patchcords were measured again after 24 hours and after one week annealing at room temperature. All patchcords with AVIM-connectors do not show noticeable attenuation increase up to 20 Mrad total dose and can be used in environments that are subjected to this level of total dose.

5.5.

Outgassing

In June of 2012, NASA tested Linden’s RAVNOC cable (p/n: 1-3-8-10-30-J-12.5-55-GRN). Values for the inner and outer jacket are as follows:

Outer Jacket:

Average Value TML (total mass loss): 0.01%

Average Value WVR (water vapor regain): 0.01%

Average Value CVCM (collected volatile

condensable materials): 0.00%

Inner Jacket:

Average Value TML: 0.06%

Average Value WVR: 0.02%

Average Value CVCM: 0.01%

6.

Conclusions

In conclusion,

  • a. LCP coated optical fiber because of low out-gassing excellent tensile properties that do not degrade after radiation exposure is an ideal candidate for space applications.

  • b. Patchcords with AVIM connectors passed most tests. However, polishing techniques need to be fine tuned to meet more stringent undercut and dome offset specifications.

REFERENCES:

1 

De Jonge, “Optical Absorption in Commercial Single Mode Optical Fibers in a High Energy Physics Radiation Field,” IEEE Trans. On Nuclear Science, 55 (4), 2216 –2222 (2008). Google Scholar

2 

Aikawa, K., “Radiation Resistant Single-Mode Optical Fibers,” Fujikura Technical Review, (2008). Google Scholar
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S. O'Riorden and A. Mahapatra "Radhard optical patchcords and packaging for satellites using liquid crystal polymers", Proc. SPIE 10564, International Conference on Space Optics — ICSO 2012, 105641I (20 November 2017); https://doi.org/10.1117/12.2309239
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
Back to Top