Open Access Paper
20 November 2017 Experimental demonstration of 1.5Hz passive isolation system for precision optical payloads
Xin Guan, Guang-yuan Wang, Dong-jing Cao, Shao-fan Tang, Xiang Chen, Lu Liang, Gang-tie Zheng
Author Affiliations +
Proceedings Volume 10565, International Conference on Space Optics — ICSO 2010; 105651Q (2017) https://doi.org/10.1117/12.2309112
Event: International Conference on Space Optics—ICSO 2010, 2010, Rhodes Island, Greece
Abstract
The ground resolution of remote sensing satellite has been raised from hundreds of meters to less than one meter in recent few decades. As a result, the precision optical payload becomes more and more sensitive to structure vibrations of satellite buses. Although these vibrations generally have extremely low magnitude, they can result in significant image quality degradation to an optical payload. The suggestion of using vibration isolators to isolate payload from the satellite bus has been put forward in 1980s’[1]. Recently, WorldView-2 achieved its perfect image quality via using a set of low frequency isolators[2]. Recently, some of the optical payload manufacturers begin to provide vibration isolators as standard parts together with their main products . During the prototype testing of an earth resource satellite, the image of the optical payload was found to jitter for 5~10 pixels due to disturbances transmitted from the satellite bus structure. Test results indicated that the acceleration level of the vibration was of mG magnitude. To solve the problem, a highly sensitive vibration isolation system was developed to reduce the transmission of disturbances. Integrated isolation performance tests showed that the image jitter can be decreased to below 0.3 pixels.

I.

INTRODUCTION

The ground resolution of remote sensing satellite has been raised from hundreds of meters to less than one meter in recent few decades. As a result, the precision optical payload becomes more and more sensitive to structure vibrations of satellite buses. Although these vibrations generally have extremely low magnitude, they can result in significant image quality degradation to an optical payload. The suggestion of using vibration isolators to isolate payload from the satellite bus has been put forward in 1980s’[1]. Recently, WorldView-2 achieved its perfect image quality via using a set of low frequency isolators[2]. Recently, some of the optical payload manufacturers begin to provide vibration isolators as standard parts together with their main products.

During the prototype testing of an earth resource satellite, the image of the optical payload was found to jitter for 5~10 pixels due to disturbances transmitted from the satellite bus structure. Test results indicated that the acceleration level of the vibration was of mG magnitude. To solve the problem, a highly sensitive vibration isolation system was developed to reduce the transmission of disturbances. Integrated isolation performance tests showed that the image jitter can be decreased to below 0.3 pixels.

II.

THEORY OF VIBRATION ISOLATION

Fig. 1. shows the dynamic model of the passive isolator. m0 is the mass of the disturbance source, k0 and c0 represent the stiffness and damping respectively of the passive isolator. p (t) is the force generated by the disturbance source and f (t) is the force transmitted to the payload.

Fig. 1.

Passive Isolation System

00233_PSISDG10565_105651Q_page_2_1.jpg

The dynamic equation of motion for this system is

00233_PSISDG10565_105651Q_page_2_2.jpg

Force transmitted to the payload structure is

00233_PSISDG10565_105651Q_page_2_3.jpg

Taking the Laplace transform on both side of Eq. (1), an expression for the vibration transmissibility can be obtained as

00233_PSISDG10565_105651Q_page_2_4.jpg

With the definition of isolation frequency and damping ratio,

00233_PSISDG10565_105651Q_page_2_5.jpg

The transmissibility can be rewritten as

00233_PSISDG10565_105651Q_page_2_6.jpg

Upon an examination of Fig. 2, it can be found that to achieve satisfactory vibration attenuation a vibration isolator should be designed with its cut-off frequency lower than the major frequencies of the disturbance forces. The damping coefficient of the isolator should also be selected to provide a proper compromise between amplification at the isolation frequency and attenuation at higher frequencies.

Fig. 2.

Transmissibility of Passive Isolation System

00233_PSISDG10565_105651Q_page_3_1.jpg

III.

DESIGN OF MICRO-VIBRATION ISOLATOR

The on-orbit vibration of the satellite structure has a very low magnitude, and its typical acceleration and displacement levels are usually several mG and μ m respectively. There is no essential difference between these micro-vibrations and vibrations with large magnitude, but vibration isolators should be specially designed to meet the new requirements arisen from such extremely low amplitude.

Some existing vibration isolation devices consist of six actuators arranged in a geometrical configuration commonly known as Stewart platform and attached to the upper and bottom brackets through hinges. Clearance of several micrometers in the kinematic pair is necessary to ensure the expected form of motion. Nevertheless, in the case of micro-vibrations, such clearance may not only prevent the spring and damper from working normally but also result in unpredictable deviation of the isolation parameters from designed values. Flexure joints are utilized in some of the recent micro-vibration isolator designs to avoid the uncertainties induced by hinge clearance [3]. Furthermore, dampers using the viscous fluid should also be avoided because of some disadvantages such as difficulty to seal, insensitive to micro-vibration, and etc. A highly sensitive damper with excellent micro-vibration damping capabilities was developed using no other materials except metal.

As shown schematically in Fig. 3., the micro-vibration isolator consists of a damper made from metal damping material. Energy is dissipated in the shearing of the damper as the piston is pumped by the vibrational displacements. Meanwhile, recovery force needed in the isolation is obtained through the deformation of the damper together with the tuning spring. Here, the tuning spring is for adjusting the whole spring stiffness to compensate the manufacture deviation of the metal damper’s stiffness. The nonlinear stiffness characteristic of the metal damping material can both provide the desired low stiffness for on-orbit micro-vibration isolation and also high stiffness necessary for surviving in the launch stage[4].

Fig. 3.

Schematic of Micro-Vibration Isolator

00233_PSISDG10565_105651Q_page_3_2.jpg

Additionally, through the design of the flexure joints at both ends, desired transverse stiffness of the isolator can be achieved. Consequently, four isolators can serve as an assembly to implement vibration isolation in all six DOFs.

IV.

DESIGN AND SIMULATION OF THE ISOLATION DEVICE

Fig. 4 shows the design configuration of the isolation device. The payload is supported by four isolators, both the axial and transverse stiffness of which can be designed as described above.

Fig. 4.

Schematic of the Isolation System

00233_PSISDG10565_105651Q_page_4_1.jpg

To achieve sufficient attenuation in the major direction of the disturbance forces and meanwhile reduce the unexpected motion in other DOFs, a design of the isolation device is conducted according to the theory presented in Section 2. The resultant normal modes of the payload are as follows in Tab. 1.

Tab. 1.

Normal Modes

Mode DescriptionNatural Frequency
Pitch1.348 Hz
Roll1.577 Hz
Vertical Translation1.606 Hz
Horizontal Translation 12.847 Hz
Horizontal Translation 22.881 Hz
Yaw3.973 Hz

A transient response analysis was carried out for the purpose of estimating the reduction in vibration magnitude due to the isolation. The finite element model of the satellite integrated with the model of the isolation system was used to perform the analysis. Time history of the acceleration response of the payload is plotted in Fig. 5, which shows that the amplitude of the response has been significantly attenuated. Compared to the non-isolated case, the RMS of the acceleration response was reduced by 99.4%.

Fig. 5.

Time History of Acceleration Response

00233_PSISDG10565_105651Q_page_4_2.jpg

V.

INTEGRATED ISOLATION PERFORMANCE TESTING

A.

Auxiliary Suspension System

Since the fundamental natural frequency of the isolation was around 1.5Hz, to avoid damage of the isolators, auxiliary suspension system must be adopted in ground isolation performance testing. This is also an important measure for simulating the zero-gravity environment on the orbit. Generally, to guarantee better testing results, the natural frequency of the suspension system should below 0.3Hz, i.e. 1/5 of the isolation system frequency. However, if tension springs were simply used to achieve this very low suspension frequency, the static deformation would be more than 3 meters, which would not be permitted by the actual condition of the laboratory. To overcome this problem, a nearly-zero Hertz suspension system was successfully developed, and a suspension frequency below 0.2Hz is achieved, which includes the contribution of electrical cables’ stiffness.

B.

Testing Configuration and Results

Payload module of the satellite was used in the integrated testing. A number of 3-axis accelerometers were arranged to ensure good surveillance of important positions on both the satellite structure and the payload. The testing was conducted in three different modes shown in Tab. 2.

Tab. 2.

Testing Modes

 DisturbanceIsolationPurpose
Mode 1OnOffDisturbance Characteristic
Mode 2OnOnIsolation Performance
Mode 3OffOnBackground Noise

Fig. 6 shows PSD of the acceleration response at one of the payload mounting points in the three testing modes described above. It can be seen that the two major contents of the disturbance were reduced by 99.5% and 99.9% respectively.

Fig. 6.

PSD of Acceleration Response

00233_PSISDG10565_105651Q_page_5_1.jpg

Tab. 3.

Attenuate Percentage of Disturbances

Measuring PointsFirst Major ContentAttenuate PercentageSecond Major ContentAttenuate Percentage
Non IsolatedIsolatedNon IsolatedIsolated 
12.91E-061.92E-0899.34%3.83E-061.45E-0899.62%
22.28E-073.73E-0998.36%1.48E-061.19E-0899.20%
31.18E-073.75E-0996.82%1.47E-064.76E-0999.68%
42.57E-061.74E-0899.32%3.48E-066.12E-0999.82%
53.58E-081.00E-0997.21%7.83E-079.55E-0998.78%
61.42E-067.48E-0999.47%1.62E-066.20E-0999.62%
71.48E-069.59E-0999.35%1.45E-066.04E-0999.58%
87.26E-081.17E-0998.39%5.47E-072.78E-0999.49%

Fig. 7 shows time history of the acceleration response at one of the payload mounting points in the three testing modes.

Fig. 7.

Time History of Acceleration Response

00233_PSISDG10565_105651Q_page_5_2.jpg

The payload was imaging the scene simulator throughout the testing to evaluate the influence of both disturbances and the isolation device. As can be seen from Fig. 8(a), the image became contorted subject to the disturbances transmitted from the satellite bus structure. In a comparison, the image shown in Fig. 8(b) is resumed to be perfectly straight with the isolation device’s functioning.

Fig. 8.

Image of the Optical Payload

00233_PSISDG10565_105651Q_page_6_1.jpg

C.

Discussions on Testing Errors

  • Background Noise

    Background noise contributed 69%~99% to the RMS of the acceleration response when the isolation device was working, as shown in Tab. 4. Since there would be no ground vibration or any sensor noise when the satellite is working on-orbit, the performance of the isolation device will be better than that in the testing. Numerical calculation result indicates that the jitter will be below 0.3 pixels.

  • Consistency between Ground Testing and On-Orbit Status

    The integrated testing was conducted with the payload module rigidly attached to a cradle whereas there will not be any constraints to the satellite on orbit. A FEM analysis was carried out to evaluate the influence on the isolation performance caused by this difference in boundary conditions and structure configurations. Results show that the isolation device will perform well both on orbit and on ground.

    As can be seen from Fig. 9 and Fig. 10, the shape of the time history response curve is similar while the amplitude of the on-orbit situation is a little bit lower compared to the fixed situation. Taking into account that there would be no air damping effect once the satellite is on the orbit, responses of the two situations should be of similar magnitude.

Fig. 9.

Time History and PSD by FEM Analysis(Fixed)

00233_PSISDG10565_105651Q_page_6_2.jpg

Fig. 10.

Time History and PSD by FEM Analysis (On Orbit)

00233_PSISDG10565_105651Q_page_7_1.jpg

Tab. 4.

Contribution of Background Noise to the Response

DirectionBackground Noise(grms)Response of Isolated System(grms)Noise Ratio
x2.2425e-0043.2360e-00469.30%
y1.7080e-0041.9288e-00488.55%
z3.2604e-0043.2838e-00499.29%

VI.

CONCLUSION

A low frequency micro-vibration isolation system was developed to attenuate disturbances transmitted to the optical payload. Integrated testing results show that the image quality has been significant improved and the image jitter can be decreased to below 0.3 pixels (when the influence of background noises is removed). Numerical simulation results with FE model of the satellite indicate that the ground test with only payload module fixed to a cradle can well simulate the on-orbit situation of whole satellite.

REFERENCES

[1] 

R.A. Laskin, S.W. Sirlin, “Future Payload Isolation and Pointing System Technology,” J.Guidance, 9 469 –477 (1986). Google Scholar

[2] 

“WorldView-2 Offers Unsurpassed Imaging Capabilities,” Earth Imaging Journal, Google Scholar

[3] 

Virginio Sannibale, Gerardo G. Ortiz, William H. Farr, “A Sub-Hertz Vibration Isolation Platform for a Deep Space Optical Communication Transceiver,” in Proc. Of SPIE, (2009). Google Scholar

[4] 

G.Y. Wang, X. Guan, X. Chen, S.F. Tang, L. Liang, “Parameter Design and Experimental Study of a Double State Nonlinear Isolatof,” Google Scholar
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xin Guan, Guang-yuan Wang, Dong-jing Cao, Shao-fan Tang, Xiang Chen, Lu Liang, and Gang-tie Zheng "Experimental demonstration of 1.5Hz passive isolation system for precision optical payloads", Proc. SPIE 10565, International Conference on Space Optics — ICSO 2010, 105651Q (20 November 2017); https://doi.org/10.1117/12.2309112
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Satellites

Optical isolators

Vibration isolation

Astronomical imaging

Passive isolation

Precision optics

Finite element methods

Back to Top