9 March 2018 Deep scatter estimation (DSE): feasibility of using a deep convolutional neural network for real-time x-ray scatter prediction in cone-beam CT
Joscha Maier, Yannick Berker, Stefan Sawall, Marc Kachelrieß
Author Affiliations +
Abstract
The contribution of scattered x-rays to the acquired projection data is a severe issue in cone-beam CT (CBCT). Due to the large cone angle, scatter-to-primary ratios may easily be in the order of 1. The corresponding artifacts which appear as cupping or dark streaks in the CT reconstruction may impair the diagnostic value of the CT examination. Therefore, appropriate scatter correction is essential. The gold standard is to use a Monte Carlo photon transport code to predict the distribution of scattered x-rays which can be subtracted from the measurement subsequently. However, long processing times of Monte Carlo simulations prohibit them to be used routinely. To enable fast and accurate scatter estimation we propose the deep scatter estimation (DSE). It uses a deep convolutional neural network which is trained to reproduce the output of Monte Carlo simulations using only the acquired projection data as input. Once the network is trained, DSE performs in real-time. In the present study we demonstrate the feasibility of DSE using simulations of CBCT head scans at different tube voltages. The performance is tested on data sets that significantly differ from the training data. Thereby, the scatter estimates deviate less than 2% from the Monte Carlo ground truth. A comparison to kernel-based scatter estimation techniques, as they are used today, clearly shows superior performance of DSE while being similar in terms of processing time.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joscha Maier, Yannick Berker, Stefan Sawall, and Marc Kachelrieß "Deep scatter estimation (DSE): feasibility of using a deep convolutional neural network for real-time x-ray scatter prediction in cone-beam CT", Proc. SPIE 10573, Medical Imaging 2018: Physics of Medical Imaging, 105731L (9 March 2018); https://doi.org/10.1117/12.2292919
Lens.org Logo
CITATIONS
Cited by 20 scholarly publications and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

X-rays

Data modeling

CT reconstruction

Convolutional neural networks

Sensors

X-ray detectors

Back to Top