You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
9 March 2018Motion-compensated reconstruction for limited-angle multiphase cardiac CT
ECG-gated multiphase cardiac CT (MP-CCT) is free of motion artifacts and can provide the extra information of cardiac functions for the diagnosis of coronary artery disease. Used majority as a screening tool, the excessive radiation dose becomes a concern of MP-CCT. In this work, we propose a motion-compensated reconstruction method for MP-CCT with the limited angle acquisition for each phase in order to substantially reduce the radiation dose. MP-CCT of the XCAT phantom with eight cardiac phases was simulated with 90° coverage for each phase. The motion was estimated from images reconstructed by combining projections from two phases (for a full 180° coverage). To reconstruct the image at phase k, the motion fields were used to warp images at phase k to phase j (j = 1~8 and j ≠ k) so that all projection data could be used for a total variation (TV) constrained reconstruction. The results show that TV reconstruction for each cardiac phase independently (TV-Single Phase) suffered severe limited-angle artifacts. TV reconstruction with two-phase projections (TV-Two Phases) improved the image quality and was suitable for good motion estimation. Motion-compensated TV reconstruction (TV-MC) achieved almost artifact-free images, although some motion errors could be seen. The root mean square error values are 254 HU, 64 HU and 47 HU for TV-Single Phase, TV-Two Phases, and TV-MC, respectively.
The alert did not successfully save. Please try again later.
Mingwu Jin, Cong Zhao, Xun Jia, Lifeng Yu, "Motion-compensated reconstruction for limited-angle multiphase cardiac CT," Proc. SPIE 10573, Medical Imaging 2018: Physics of Medical Imaging, 1057333 (9 March 2018); https://doi.org/10.1117/12.2294922