Paper
20 February 2018 The design of visible system for improving the measurement accuracy of imaging points
Author Affiliations +
Proceedings Volume 10697, Fourth Seminar on Novel Optoelectronic Detection Technology and Application; 106971L (2018) https://doi.org/10.1117/12.2314915
Event: Fourth Seminar on Novel Optoelectronic Detection Technology and Application, 2017, Nanjing, China
Abstract
It has a widely applications in robot vision and 3D measurement for binocular stereoscopic measurement technology. And the measure precision is an very important factor, especially in 3D coordination measurement, high measurement accuracy is more stringent to the distortion of the optical system. In order to improving the measurement accuracy of imaging points, to reducing the distortion of the imaging points, the optical system must be satisfied the requirement of extra low distortion value less than 0.1%, a transmission visible optical lens was design, which has characteristic of telecentric beam path in image space, adopted the imaging model of binocular stereo vision, and imaged the drone at the finity distance. The optical system was adopted complex double Gauss structure, and put the pupil stop on the focal plane of the latter groups, maked the system exit pupil on the infinity distance, and realized telecentric beam path in image space. The system mainly optical parameter as follows: the system spectrum rangement is visible light wave band, the optical effective length is f ’=30mm, the relative aperture is 1/3, and the fields of view is 21°. The final design results show that the RMS value of the spread spots of the optical lens in the maximum fields of view is 2.3μm, which is less than one pixel(3.45μm); the distortion value is less than 0.1%, the system has the advantage of extra low distortion value and avoids the latter image distortion correction; the proposed modulation transfer function of the optical lens is 0.58(@145 lp/mm), the imaging quality of the system is closed to the diffraction limited; the system has simply structure, and can satisfies the requirements of the optical indexes. Ultimately, based on the imaging model of binocular stereo vision was achieved to measuring the drone at the finity distance.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Qiu-sha Shan, Gang Li, Luan Zeng, Kai Liu, Pei-pei Yan, Jing Duan, and Kai Jiang "The design of visible system for improving the measurement accuracy of imaging points", Proc. SPIE 10697, Fourth Seminar on Novel Optoelectronic Detection Technology and Application, 106971L (20 February 2018); https://doi.org/10.1117/12.2314915
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Imaging systems

Distortion

Monochromatic aberrations

Optical design

Image quality

Refractive index

Glasses

RELATED CONTENT

Design of zoom lens with binary optics
Proceedings of SPIE (October 05 1995)
Optical system design of descent camera
Proceedings of SPIE (December 09 2005)

Back to Top