Paper
6 July 2018 Independent images: a need for phantom based image quality assessment using model observers?
Author Affiliations +
Proceedings Volume 10718, 14th International Workshop on Breast Imaging (IWBI 2018); 107181N (2018) https://doi.org/10.1117/12.2317600
Event: The Fourteenth International Workshop on Breast Imaging, 2018, Atlanta, Georgia, United States
Abstract
The use of model observers for image quality assessment in digital mammography is currently being considered. Model observers assign decision variables to signal present and signal absent images which, if they are independent, can be used as a measure of performance. In this study, the impact of different dependencies at pixel level between the signal present and signal absent images were studied for the detection of 0.25 mm and 2.5 mm diameter disk-shaped objects. Clinical images were acquired on an Amulet Innovality (FujiFilm, Tokio, Japan) mammography unit and modified multiple times to appear as acquired at 75% of the original dose level and to simulate different noise realizations. From these modified images, regions of interest (ROIs), with and without an embedded signal were obtained. Subsequently, detection experiments were created for which the images with and without embedded signals had: 1) exactly the same background structures, 2) the same background structures but different quantum noise realizations, and 3) completely different background structures. The ROIs were evaluated using a channelized Hotelling observer (CHO) with a dense difference of Gaussian channel set. It was found that if the background structures within the ROIs with and without signal are dependent, the CHO decision variables also show strong dependencies. However, the performance measurement of the CHO yielded values that were not affected by the dependency in pixel values. This finding is important for future developments of phantom-based image quality analysis in mammography using model observers when using a single or a limited number of anthropomorphic phantoms.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ramona W. Bouwman, Christiana Balta, David R. Dance, Kenneth C. Young, Alistair Mackenzie, Ioannis Sechopoulos, and Ruben E. van Engen "Independent images: a need for phantom based image quality assessment using model observers?", Proc. SPIE 10718, 14th International Workshop on Breast Imaging (IWBI 2018), 107181N (6 July 2018); https://doi.org/10.1117/12.2317600
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

Breast

Signal detection

Signal to noise ratio

Mammography

Image processing

Image analysis

Back to Top