Presentation + Paper
5 October 2018 A new polarimetric passive radar calibrator for fully polarimetric measurement
Author Affiliations +
Abstract
Conventionally, for the fully polarimetrical calibration of a general non-reciprocal radar system, at least two calibrators such as a dihedral corner reflector plus a sphere are required. A new polarimetric passive radar calibrator for fully polarimetric calibration is proposed in this paper. With the new design, a single calibrator is enough for the same purpose. The electromagnetic scattering characteristic of the new calibrator is calculated by method of moment (MOM), demonstrating that the new calibrator is suitable for fully polarimetric calibration applications.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pengfei Wu and Xiaojian Xu "A new polarimetric passive radar calibrator for fully polarimetric measurement", Proc. SPIE 10800, Millimetre Wave and Terahertz Sensors and Technology XI, 1080008 (5 October 2018); https://doi.org/10.1117/12.2503532