During radiotherapy, X-ray beams induce Cherenkov light emission in tissue as part of the dose delivery. This light can be used for dosimetry, in order to track and image the dose as it happens. The Cherenkov light levels are in the range of 10−6 to 10−9 W∕cm2, which makes it challenging to detect in a clinical environment. However, because the radiation is pulsed in 4 microsecond bursts, time-gated acquisition of the signal allows for robust detection, even in the presence of ambient room lighting. Thus, imaging sensors for this application must be highly sensitive and must be able to time gate faster than a microsecond. In this study, the use of a solid-state detector composed of 64×32 single photon avalanche diodes (SPADs) was examined. The advantages of this technology were intra-chip amplification, high dynamic range, superior X-ray noise rejection and fast temporal gating of the acquisition. The results show that the SPAD camera was sensitive enough to detect Cherenkov radiation despite the 3% fill factor. 2D oversampling (×25) was also used to increase final image resolution to 320×160. In this work we demonstrate the SPAD camera performance in imaging Cherenkov emission from a tissue optical phantom and one patient undergoing radiotherapy. The results show that the SPAD camera was sensitive enough to detect Cherenkov radiation emitted from patient’s surface with signal-to-noise ratio of 14 after 6s acquisition. The SPAD camera sensors could be a viable alternative for Cherenkov imaging, as compared to current imaging methods that are mostly focused around image intensifier-based cameras and so have a range of non-linearities and instabilities which could be solved by an all solid-state camera sensor.
Conference Presentation
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. Pétusseau, P. Bruza, S. Tisa, S. Gioux, and B. W. Pogue "SPAD based imaging of Cherenkov light in radiation therapy", Proc. SPIE 10862, Molecular-Guided Surgery: Molecules, Devices, and Applications V, 108621B (7 March 2019); https://doi.org/10.1117/12.2507987
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

X-rays

Sensors

Radiotherapy

X-ray imaging

Photodetectors

Cerenkov radiation imaging

RELATED CONTENT


Back to Top