You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
1 March 2019Image-based deformable motion compensation for interventional cone-beam CT
Purpose: Interventional cone-beam CT (CBCT) is used for 3D guidance in interventional radiology (IR) procedures in the abdomen, with extended presence in trans-arterial chemoembolization (TACE) interventions for liver cancer. Image quality in this scenario is challenged by complex motion of soft-tissue abdominal structures, and by long acquisition times. We propose an image-based approach to estimate complex deformable motion through a combination of locally rigid motion trajectories. Methods: Deformable motion is estimated by minimizing a multi-region autofocus cost function. Motion is considered locally rigid for each region of interest (ROI) and the deformable motion field is obtained through spatial spline-based interpolation of the local trajectories. The multi-component cost function includes two regularization terms; one to penalize abrupt temporal transitions, and another to penalize abrupt spatial changes in the trajectory. Performance of deformable motion compensation was assessed in simulation studies with a digital abdomen phantom featuring a motion-induced deformable liver in static surrounding anatomy. Spherical inserts (4 – 12 mm diameter, -100 – 100 HU contrast) were placed in the liver. Image quality was evaluated by structural similarity (SSIM) with the static image as reference. Results: Motion compensated liver images showed better delineation of structure boundaries and recovery of distorted spherical shapes compared to their motion-corrupted counterparts. Consistent increase in SSIM was observed after motion compensation for the range of motion amplitudes studied (4 mm to 10 mm), showing 11% and 26% greater SSIM for 4 mm and 10 mm motion, respectively. Conclusion: The results indicate feasibility of image-based deformable motion compensation in soft-tissue abdominal CBCT imaging.
The alert did not successfully save. Please try again later.
A. Sisniega, S. Capostagno, W. Zbijewski, C. R. Weiss, T. Ehtiati, J. H. Siewerdsen, "Image-based deformable motion compensation for interventional cone-beam CT," Proc. SPIE 10948, Medical Imaging 2019: Physics of Medical Imaging, 109481O (1 March 2019); https://doi.org/10.1117/12.2513446