Paper
7 March 2019 Optical fiber Fabry-Perot acoustic sensor based on large PDMS diaphragm
Author Affiliations +
Proceedings Volume 11053, Tenth International Symposium on Precision Engineering Measurements and Instrumentation; 110531W (2019) https://doi.org/10.1117/12.2511691
Event: 10th International Symposium on Precision Engineering Measurements and Instrumentation (ISPEMI 2018), 2018, Kunming, China
Abstract
An extrinsic Fabry-Perot interferometric fibre microphone based on polydimethylsiloxane, or PDMS, diaphragm was proposed. The large free-standing PDMS diaphragm, with a diameter of 4 mm, is prepared by a simple “spin-strip” process. The experimental result shows that the fabricated sensor has a high dynamic pressure sensitivity of about -136 dB re 1 rad/μPa in the range of 100~2000Hz. The noise equivalent acoustic signal level of the microphone, limited by the environmental noise, is about 1000 μPa/Hz1/2. And the dynamic range is tested to be more than 47.48 dB. The proposed microphone is expected to be used in the field of weak acoustic pressure testing.
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Han Zhou, Bingkun Wu, Mingguang Shan, Lei Liu, Haichao Yu, Zhi Zhong, and Bin Liu "Optical fiber Fabry-Perot acoustic sensor based on large PDMS diaphragm", Proc. SPIE 11053, Tenth International Symposium on Precision Engineering Measurements and Instrumentation, 110531W (7 March 2019); https://doi.org/10.1117/12.2511691
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Acoustics

Fabry–Perot interferometers

Optical fibers

Silicon

Glasses

Ceramics

Back to Top