You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
28 May 2019Bulk motion detection and correction using list-mode data for cardiac PET imaging
Purpose: Image quality of cardiac PET is degraded by cardiac, respiratory, and bulk motion. The purpose of this work is to use PET list-mode data to detect and correct for bulk motion, which is unpredictable and must therefore be tracked at all times. Methods: We propose a data-driven approach that can detect and compensate bulk motion in cardiac PET imaging. Events in a motion-contaminated scan are binned into static (without intra-frame motion) and moving (with intra-frame motion) frames based on the variance of the center positions of line-of-responses calculated in each 1-second time window. Each moving frame is further divided into subframes, within which no motion is assumed. Data in each static and sub-moving-frame are then back-projected to the image space. The resulting images are used to estimate motion transformation from all static and sub-moving frames to a selected static reference frame. Finally, the data in all the frames are jointly reconstructed by incorporating motion estimation in the system matrix. We have applied our method to three human cardiac PET studies. Results: Visual assessment indicated the greatly improved image quality of the motion-corrected image over non-motion-corrected image. Also, motion correction yielded higher myocardium to blood pool concentration ratios than non-motion correction. Conclusion: The proposed bulk motion correction method improves the image quality of cardiac PET and can potentially be applied to other PET imaging applications such as brain PET.
The alert did not successfully save. Please try again later.
Tao Sun, Yoann Petibon, Paul Han, Chao Ma, Sally J. W. Kim, Nathaniel M. Alpert, Georges El Fakhri, Jinsong Ouyang, "Bulk motion detection and correction using list-mode data for cardiac PET imaging," Proc. SPIE 11072, 15th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, 110722F (28 May 2019); https://doi.org/10.1117/12.2534701