Paper
19 February 2020 A new technique for estimating the foveal avascular zone dimensions
Author Affiliations +
Proceedings Volume 11218, Ophthalmic Technologies XXX; 112181R (2020) https://doi.org/10.1117/12.2543906
Event: SPIE BiOS, 2020, San Francisco, California, United States
Abstract
The Foveal Avascular Zone (FAZ) is of clinical importance since the vascular arrangement around the fovea changes with disease and refractive state of the eye. Therefore, it is important to segment and quantify the FAZs accurately. Here we provide a new methodology for this measurement. Eighty normal fundus images of dimensions 420x420 pixels corresponding to 6mm x 6mm were used in this study. Each fundus image was manually segmented by a clinical expert (ground truth), the new methodology and an existing technique provided by the image acquisition device (Cirrus 5000 Carl Zeiss Meditec Inc., Dublin, CA). The images were first processed by a Difference of Gaussian (DoG) filter iteratively 25 times after being complemented. This is followed by a Prewitt edge detection and repeated image dilation at angles of 0,45 and 90 degrees. Image closure was then applied followed by noise and small object removal which resulted in the segmented boundary. For deeper insight into shape change, besides the diameter of the FAZ other parameters - eccentricity, perimeter, major axis, minor axis, incircle, circumcircle, Fmin, Fmax, tortuosity, vessel diameter index and vessel avascular density - were calculated. The mean diameter by manual segmentation was 673.04 ± 86.92 μm compared to 688.42 ± 72.18 μm by our technique. The corresponding value generated by the instrument was 623.60 ± 121.50 μm. This technique shows considerable improvement in accuracy (the mean value as well as the standard deviation) when compared to system segmentation and the ground truth. These aspects will be discussed in the paper.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arpit Agarwal, J. Jothi Balaji, and Vasudevan Lakshminarayanan "A new technique for estimating the foveal avascular zone dimensions", Proc. SPIE 11218, Ophthalmic Technologies XXX, 112181R (19 February 2020); https://doi.org/10.1117/12.2543906
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image segmentation

Image processing

Image filtering

Edge detection

Eye

Gaussian filters

Angiography

Back to Top