You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
16 March 2020Three-dimensional ultrasound for monitoring knee inflammation and cartilage damage in osteoarthritis and rheumatoid arthritis
The most common chronic inflammatory and chronic joint diseases in Canada are rheumatoid arthritis (RA) and osteoarthritis (OA) respectively. The current methods for monitoring the development of these diseases and their response to treatment involve acquiring x-ray and magnetic resonance imaging (MRI) images and comparing the results to the patient’s symptoms during examination. However, x-ray imaging is associated with difficulties when trying to interpret 3D anatomy, and MRI is associated with high operating costs, long waitlists, long scan times, and is inaccessible to mobility-impaired patients. Our solution to these limitations is the use of three-dimensional ultrasound (3D US) imaging for providing bedside monitoring of RA and OA progression and their response to treatment. This project validates two 3D US acquisition devices: tilt acquisition and linear acquisition scanning methods. The linear and volumetric measurement capabilities were validated through scanning phantoms and segmenting resulting images at repeated time points. A proof-of-concept volunteer scan was conducted to compare the capabilities of 3D US against MRI for measuring articular cartilage volumes. Results indicated that the linear measurement errors for both the tilt and linear scanners were <5% of the known phantom dimensions. The volumetric measurement errors were <5% for the linear scanner and >10% (29.84%) for the tilt scanner. The percent difference between the volumes of the articular cartilage measured using 3D US and MRI of a healthy volunteer’s knee was 6.46%. The linear scanner is therefore better suited for clinical scanning than the tilt scanner due to its smaller linear and volumetric errors.
Sam Papernick,Derek J. Gillies,Tom Appleton, andAaron Fenster
"Three-dimensional ultrasound for monitoring knee inflammation and cartilage damage in osteoarthritis and rheumatoid arthritis", Proc. SPIE 11315, Medical Imaging 2020: Image-Guided Procedures, Robotic Interventions, and Modeling, 113150E (16 March 2020); https://doi.org/10.1117/12.2549624
The alert did not successfully save. Please try again later.
Sam Papernick, Derek J. Gillies, Tom Appleton, Aaron Fenster, "Three-dimensional ultrasound for monitoring knee inflammation and cartilage damage in osteoarthritis and rheumatoid arthritis," Proc. SPIE 11315, Medical Imaging 2020: Image-Guided Procedures, Robotic Interventions, and Modeling, 113150E (16 March 2020); https://doi.org/10.1117/12.2549624