You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
16 March 2020Automated segmentation of computed tomography colonography images using a 3D U-Net
PURPOSE: The segmentation of Computed Tomography (CT) colonography images is important to both colorectal research and diagnosis. This process often relies on manual interaction, and therefore depends on the user. Consequently, there is unavoidable interrater variability. An accurate method which eliminates this variability would be preferable. Current barriers to automated segmentation include discontinuities of the colon, liquid pooling, and that all air will appear the same intensity on the scan. This study proposes an automated approach to segmentation which employs a 3D implementation of U-Net. METHODS: This research is conducted on 76 CT scans. The U-Net comprises an analysis and synthesis path, both with 7 convolutional layers. By nature of the U-Net, output segmentation resolution matches the input resolution of the CT volumes. K-fold cross-validation is applied to ensure no evaluative bias, and accuracy is assessed by the Sørensen-Dice coefficient. Binary cross-entropy is employed as a loss metric. RESULTS: Average network accuracy is 98.81%, with maximum and minimum accuracies of 99.48% and 97.03% respectively. Standard deviation of K accuracies is 0.5%. CONCLUSION: The network performs with considerable accuracy, and can reliably distinguish between colon, small intestine, lungs, and ambient air. A low standard deviation is indicative of high consistency. This method for automatic segmentation could prove a supplemental or alternative tool for threshold-based segmentation. Future studies will include an expanded dataset and a further optimized network.
The alert did not successfully save. Please try again later.
Keiran Barr, Jacob Laframboise, Tamas Ungi, Lawrence Hookey, Gabor Fichtinger, "Automated segmentation of computed tomography colonography images using a 3D U-Net," Proc. SPIE 11315, Medical Imaging 2020: Image-Guided Procedures, Robotic Interventions, and Modeling, 113152G (16 March 2020); https://doi.org/10.1117/12.2549749