Paper
27 November 1989 Fabrication And Test Of X-Ray Optics
Klaus Beckstette
Author Affiliations +
Abstract
A review on state of the art fabrication and test methods for grazing incidence X-ray optics is given with the main emphasis on optics used in synchrotron radiation beam lines. Key topics to be discussed are: Substrate materials, dimensions, properties, surface characteristics. Steps in manufacturing and polishing of aspherical elements. Special problems of manufacturing aspherical elements versus manufacturing spherical elements. Test methods and available testing facilities. Influence of form, surface finish and tolerance on manufacturing complexity.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Klaus Beckstette "Fabrication And Test Of X-Ray Optics", Proc. SPIE 1140, X-Ray Instrumentation in Medicine and Biology, Plasma Physics, Astrophysics, and Synchrotron Radiation, (27 November 1989); https://doi.org/10.1117/12.961841