The results of investigation of the absorption spectra of ascorbic acid solutions with varying pH value are presented. The acidity of the solutions changed with increasing concentration, with the addition of hydrogen peroxide and sodium hydroxide. It was found that the position of the maximum absorption of ascorbic acid solutions depends on the pH value. The position of the absorption maxima shifts from 243 nm to 268 nm if the pH increases from 2 to 9. The change in the spectra is due to the stronger oxidation of ascorbic acid in alkaline solutions, which is accompanied by the removal of protons.
Julia Danyaeva,Svetlana Kutsenko, andNatalya Kudrya
"The change in the absorption spectra of ascorbic acid solutions, depending on their acidity", Proc. SPIE 11457, Saratov Fall Meeting 2019: Optical and Nano-Technologies for Biology and Medicine, 114571H (9 April 2020); https://doi.org/10.1117/12.2564342
ACCESS THE FULL ARTICLE
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Julia Danyaeva, Svetlana Kutsenko, Natalya Kudrya, "The change in the absorption spectra of ascorbic acid solutions, depending on their acidity," Proc. SPIE 11457, Saratov Fall Meeting 2019: Optical and Nano-Technologies for Biology and Medicine, 114571H (9 April 2020); https://doi.org/10.1117/12.2564342