Poster + Paper
20 August 2020 Long term stability monitoring of Aqua MODIS thermal emissive bands through radiative transfer modeling
Author Affiliations +
Conference Poster
Abstract
Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been in operation providing continuous global observations for science research and applications since 2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitored through inter-comparisons with measurements by hyperspectral infrared sensors, such as AIRS on Aqua and IASI on MetOp satellite, or through long term vicarious monitoring over cold targets, such as Dome- C and deep convective clouds (DCC). In this paper, a radiative transfer modeling-based simulation model using Community Radiative Transfer Model (CRTM) is developed to perform the long-term monitoring of the stability of TEBs of Aqua MODIS. CRTM is a fast-radiative transfer model for calculations of radiances for satellite infrared radiometers and is able to output infrared radiance and brightness temperature at spectral bands of MODIS. Long term European Centre for Medium-Range Weather Forecasts (ECMWF) global atmospheric reanalysis data, such as temperature and humidity profiles, are used as inputs to the CRTM simulation. By confining the area of interest to be over low to middle latitude ocean, the long-term stabilities of selected Aqua MODIS TEBs are monitored through Observation–Background (O-B) brightness temperature (BT) bias between MODIS measurements and BT retrieval from CRTM simulation. The consistency and relative stability between Aqua MODIS and ECMWF reanalysis data for surface channels of MODIS are evaluated. In addition, the radiative transfer modeling with CRTM enables us to evaluate the impacts of long term variation of global CO2 distribution on the O-B BT biases for CO2 channels of Aqua MODIS through comparison of simulations with constant or long term variable CO2 as inputs. The O-B analysis with RTM show that Aqua MODIS surface channels are all radiometrically stable with yearly BT bias drift less than 0.004K/year for B20, B22, B23 and ~0.01K/year for B31 and B32. The CO2 absorption channels of Aqua MODIS, e.g. B33-B36, are stable with BT bias drift < 0.005K/year.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tung-Chang Liu, Xiaoxiong Xiong, Xi Shao, Yong Chen, Aisheng Wu, Tiejun Chang, and Ashish Shrestha "Long term stability monitoring of Aqua MODIS thermal emissive bands through radiative transfer modeling", Proc. SPIE 11501, Earth Observing Systems XXV, 115011K (20 August 2020); https://doi.org/10.1117/12.2568052
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
MODIS

Absorption

Radiative transfer

Infrared radiation

Data modeling

RELATED CONTENT

Water Vapor Continuum Absorption In The Infrared
Proceedings of SPIE (December 19 1979)
MODTRAN5: 2006 update
Proceedings of SPIE (May 08 2006)
Far IR measurements at Cerro Toco, Chile FIRST, REFIR,...
Proceedings of SPIE (September 20 2010)

Back to Top