Paper
5 November 2020 Position sensitive micro-channel plate based photon counting three-dimensional imaging for long space objects: simulation and characteristics analysis
Haomeng Yin, Hui Zhao, Yong'an Liu, Siyu Xia, Xuewu Fan, Lizhi Sheng
Author Affiliations +
Proceedings Volume 11567, AOPC 2020: Optical Sensing and Imaging Technology; 115672V (2020) https://doi.org/10.1117/12.2580007
Event: Applied Optics and Photonics China (AOPC 2020), 2020, Beijing, China
Abstract
Position sensitive micro-channel plate (MCP ) is a kind of high sensitivity detector with low noise, Combined with advanced time-correlated single photon imaging technique (TCSPC) could make a moderate aperture system be sensitive to only one single arriving photon. In this paper, a theoretical model of photon counting imaging with Position sensitive MCP was established and the factor of laser power affecting the detect possibility was analyzed. the three-dimensional point clouds data are generated using Monte Carlo simulation and the typical space target could be reconstructed three-dimensionally. Through the all-chain simulation model the comprehensive performance of the MCP based active three-dimensional imaging system could be analyzed from viewpoint of detection probability, ranging accuracy and signal to noise ratio etc. The application of the position sensitive MCP based active three-dimensional imaging system for long range space objects is verified in simulation condition. The results shows that only a single pulse energy of tens of mico-Joule is needed for the positive sensitive MCP based active three-dimensional imaging system to image the target at the hundreds of kilometers. the counting rate could reach 106 counts/s. And the ranging accuracy of this active three-dimensional imaging system for the objects at 300 kilometers could reach 0.1228meters by simulating with 50 mico-Joule single pulse power.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Haomeng Yin, Hui Zhao, Yong'an Liu, Siyu Xia, Xuewu Fan, and Lizhi Sheng "Position sensitive micro-channel plate based photon counting three-dimensional imaging for long space objects: simulation and characteristics analysis", Proc. SPIE 11567, AOPC 2020: Optical Sensing and Imaging Technology, 115672V (5 November 2020); https://doi.org/10.1117/12.2580007
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Target detection

Signal to noise ratio

3D image processing

Imaging systems

Sensors

Laser energy

Microchannel plates

RELATED CONTENT

Three-dimensional active imaging using compressed gating
Proceedings of SPIE (September 19 2013)
Research status of laser active imaging detection
Proceedings of SPIE (November 05 2020)
Target detection against strong light based on gate viewing
Proceedings of SPIE (November 28 2011)
Eye-safe laser radar 3D imaging
Proceedings of SPIE (September 13 2004)
Detection performance of laser range-gated imaging system
Proceedings of SPIE (October 22 2010)

Back to Top