Paper
1 July 1990 Comparison of the physical performance of high-resolution CRT displays and films recorded by laser image printers and displayed on light-boxes and the need for a display standard
Author Affiliations +
Abstract
Performance figures are reported on absolute luminance, luminance uniformity, characteristic display function, internal scatter, dynamic range, distortion, modulation transfer and its spatial uniformity, and temporal and spatial noise of two commercial ORT display systems as well as films printed by laser image recorders and displayed on light-boxes. One of the ORT displays has a matrix of nominally 2000 x 2000 pixels, the other of 1000 x 1500 pixels. The laser image recorders cover a matrix of 3500 x 2200 pixels. When comparing equal pixel matrices of hard versus soft copy displays, typically hard copies facilitate greater information transfer than soft copies due to a presentation with higher absolute luminance, greater perceived dyiiainic range, and better spatial resolution. Perceived dynamic range and resolution are partially degraded in the ORT displays by internal scatter. Soft and hard copy displays are about equivalent in terms of luminance non-uniformity, noise, and geometrical distortion. All displays differ in their characteristic display functions and thus in perceived contrast resolution. A display function standard is proposed to the industry by which mismatches between hard and soft copy presentations can be nimized as well as means for maintaining standardized performance.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hartwig R. Blume, Hans Roehrig, Michael P. Browne, and Tinglan Ji "Comparison of the physical performance of high-resolution CRT displays and films recorded by laser image printers and displayed on light-boxes and the need for a display standard", Proc. SPIE 1232, Medical Imaging IV: Image Capture and Display, (1 July 1990); https://doi.org/10.1117/12.18846
Lens.org Logo
CITATIONS
Cited by 35 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
CRTs

Modulation

Medical imaging

Image quality

Signal to noise ratio

Image quality standards

Distortion

RELATED CONTENT

Hard copies for digital medical images: an overview
Proceedings of SPIE (April 27 1995)
Practical usage of image quality verification tools
Proceedings of SPIE (August 07 2001)
Medically adapted JPEG compression scheme
Proceedings of SPIE (April 27 1995)
Image quality--critical to PACS
Proceedings of SPIE (June 30 1993)

Back to Top