We report 6 kW pump limited power handling in a 7+1 to 1 Pump-Signal Combiner. The high pump transmission efficiency of 98% and optimal thermal management of the combiner package enables a low thermal slope of 0.0037 C/W measured up to 6 kW of pump power. The low thermal slope allows for a potential 9 kW pump power handling capacity of the 7+1 to 1 combiner.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
L. Bansal, J. Pincha, R. Sienkowski, C. Neale, J. Mann, J. W. Nicholson, "6 kW power handling in a 7+1 to 1 pump-signal combiner," Proc. SPIE 12402, Components and Packaging for Laser Systems IX, 1240207 (17 March 2023); https://doi.org/10.1117/12.2649274