28 August 2024 Integration and site acceptance testing of light sources and sensors for automated beam train alignment at the MROI
Author Affiliations +
Conference Poster
Abstract
Beam misalignment causes visibility loss in fringe measurements made by long-baseline optical interferometers. An Automated Alignment System (AAS) has been designed for the Magdalena Ridge Observatory Interferometer (MROI) to keep the visibility loss associated with misalignment under ∼1%. Production versions of collimated reference light sources and precision beam alignment sensors for the AAS have recently been integrated into the first beamline of the MROI. This paper describes the lessons learned during their installation and provides results from their site acceptance tests.
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
James J. D. Luis, Juan Altamirano, David F. Buscher, Michelle J. Creech-Eakman, Christopher A. Haniff, Jeffrey C. Mason, Hamed Momeni, Siavash Norouzi, Andres Olivares, Chris Salcido, Rafael Santoro, Ian Schofield, Eugene B. Seneta, and John S. Young "Integration and site acceptance testing of light sources and sensors for automated beam train alignment at the MROI", Proc. SPIE 13095, Optical and Infrared Interferometry and Imaging IX, 130952B (28 August 2024); https://doi.org/10.1117/12.3021179