Paper
1 November 1990 Two-dimensional delay-line anode detector for astronomical imaging
Peter G. Friedman, Christopher Martin, Andrew Rasmussen
Author Affiliations +
Abstract
Progress is reported in the development and testing of a microchannel-plate anode detector for a satellite-based all-sky survey in the FUV. A preliminary FWHM-resolution value of 6- microns and a linearity of 15 microns have been achieved. Optimization of the electronics should improve the resolution by a factor of four and improve the linearity to 10 microns over the entire field. It should be possible to increase the detector format to hundreds of sq cm with no degradation of resolution or increase in complexity.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter G. Friedman, Christopher Martin, and Andrew Rasmussen "Two-dimensional delay-line anode detector for astronomical imaging", Proc. SPIE 1344, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy, (1 November 1990); https://doi.org/10.1117/12.23250
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Electrons

Electronics

X-ray astronomy

Image resolution

Extreme ultraviolet

Gamma radiation

RELATED CONTENT

Calibration of the ROSAT High-Resolution Imager
Proceedings of SPIE (November 01 1990)
High-dynamic-range MCP structures
Proceedings of SPIE (October 01 1991)
SPAN: a novel high-speed high-resolution position readout
Proceedings of SPIE (November 01 1990)
Background reduction in microchannel plates
Proceedings of SPIE (November 01 1990)
Performance characteristics of SPAN position readout systems
Proceedings of SPIE (October 08 1992)

Back to Top