Translator Disclaimer
Paper
16 September 1992 NVEOD FLIR92 thermal imaging systems performance model
Author Affiliations +
Abstract
The Night Vision and Electro-Optics Directorate's FLIR92 model predicts minimum resolvable temperature difference (MRTD) and minimum detectable temperature difference (MDTD) for scanning and staring infrared sensors. FLIR92 retains unchanged for two- dimensional MRTD, and incorporates sampling effects and three-dimensional noise more thoroughly than the simple approximations used in the FLIR90 model. The FLIR92 MRTD predictions are shown to be valid for representative scanning and staring systems.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Luke B. Scott and John A. D'Agostino "NVEOD FLIR92 thermal imaging systems performance model", Proc. SPIE 1689, Infrared Imaging Systems: Design, Analysis, Modeling, and Testing III, (16 September 1992); https://doi.org/10.1117/12.137950