Paper
7 July 1993 Bubble formation during pulsed laser ablation: mechanism and implications
Ton G. J. M. van Leeuwen, E. Duco Jansen, Massoud Motamedi, Ashley J. Welch, Cornelius Borst M.D.
Author Affiliations +
Proceedings Volume 1882, Laser-Tissue Interaction IV; (1993) https://doi.org/10.1117/12.147658
Event: OE/LASE'93: Optics, Electro-Optics, and Laser Applications in Scienceand Engineering, 1993, Los Angeles, CA, United States
Abstract
Holmium ((lambda) equals 2.09 micrometers ) and excimer ((lambda) equals 308 nm) lasers are used for ablation of tissue. In a previous study it was demonstrated that both excimer and holmium laser pulses produce fast expanding and collapsing vapor bubbles. To investigate whether the excimer induced bubble is caused by vaporization of water, the threshold fluence for bubble formation at a bare fiber tip in water was compared between the excimer laser (pulse length 115 ns) and the Q-switched and free-running holmium lasers (pulse length 1 microsecond(s) to 250 microsecond(s) , respectively). To induce bubble formation by excimer laser light in water, the absorber oxybuprocaine-hydrochloride (OBP-HCl) was added to the water. Fast flash photography was used to measure the threshold fluence as a function of the water temperature (6 - 90 degree(s)C) at environmental pressure. The ultraviolet excimer laser light is strongly absorbed by blood. Therefore, to document the implications of bubble formation at fluences above the tissue ablation threshold, excimer laser pulses were delivered in vitro in hemoglobin solution and in vivo in the femoral artery of the rabbit. We conclude that the principal content of the fast bubble induced by a 308 nm excimer laser pulse is water vapor. Therefore, delivery of excimer laser pulses in a water or blood environment will cause fast expanding water vapor bubbles, which may induce mechanical damage to adjacent tissue.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ton G. J. M. van Leeuwen, E. Duco Jansen, Massoud Motamedi, Ashley J. Welch, and Cornelius Borst M.D. "Bubble formation during pulsed laser ablation: mechanism and implications", Proc. SPIE 1882, Laser-Tissue Interaction IV, (7 July 1993); https://doi.org/10.1117/12.147658
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Excimer lasers

Laser tissue interaction

Holmium

Laser damage threshold

Pulsed laser operation

Laser ablation

Excimers

Back to Top