Paper
1 February 1994 Speckle photography in biomechanical testing
Author Affiliations +
Abstract
The application of speckle photography in biomechanical testing of bones and surgical fixing devices is presented. Double-exposure speckle photography is used for measuring the in-plane deformation of broken lower leg bones supported with different fixing devices under axial loading. An osteosynthesis plate, an external fixator, and an intramedullar nail mounted on the tibia shaft are tested. The results for different loading conditions are analyzed and compared with those obtained by holographic interferometry. Further, the human hyoid bone is investigated by this method. The load is applied to the anterior surface of the body of the bone. All tested specimen show an asymmetric displacement, the greatest in a plane vertical to the load. An evaluation of fracture behavior can be done from the displacement pattern.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Henryk T. Kasprzak and Halina Podbielska M.D. "Speckle photography in biomechanical testing", Proc. SPIE 2083, Microscopy, Holography, and Interferometry in Biomedicine, (1 February 1994); https://doi.org/10.1117/12.167444
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Bone

Speckle

Photography

Holographic interferometry

Speckle pattern

Dysprosium

Transparency

Back to Top