15 July 1994 Thermoelectrically cooled MWIR HgCdTe image sensors
Paul R. Norton, Michael Bailey, Ichiro Kasai, Peter J. King
Author Affiliations +
Abstract
Photovoltaic mercury cadmium telluride IR detector arrays having spectral response in the medium wavelength IR region out to 5 micrometers have been developed for thermal imaging applications. These detectors require cooling only to 180 K which can be provided by a thermoelectric cooler having six stages. The detectors have achieved noise-equivalent temperature difference performance less than 0.05 degree(s)C for an f/1.6 optical field of view. They are commercially available in a permanently sealed metal package with ceramic feedthroughs and a sapphire window.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Paul R. Norton, Michael Bailey, Ichiro Kasai, and Peter J. King "Thermoelectrically cooled MWIR HgCdTe image sensors", Proc. SPIE 2225, Infrared Detectors and Focal Plane Arrays III, (15 July 1994); https://doi.org/10.1117/12.179707
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mercury cadmium telluride

Image sensors

Mid-IR

Sensors

Thermography

Detector arrays

Infrared detectors

RELATED CONTENT

Small pixel cross talk MTF and its impact on MWIR...
Proceedings of SPIE (May 03 2017)
Next decade in infrared detectors
Proceedings of SPIE (October 09 2017)
Choosing detectors for third-generation infrared systems
Proceedings of SPIE (January 23 2003)
Uncooled dual-band MWIR/LWIR optical readout imager
Proceedings of SPIE (April 16 2008)
256 x 256 PACE 1 PV HgCdTe focal plane arrays...
Proceedings of SPIE (September 01 1990)

Back to Top