Paper
7 December 1994 Reticle correction technique to minimize lens distortion effects
Warren W. Flack, Gary E. Flores, Alan D. Walther, Manny Ferreira
Author Affiliations +
Abstract
In this study, the distortion signature of an Ultratech 2244i lens was measured using an advanced registration measurement system. A correction for this distortion signature was applied to the design database and a mix-and-match test reticle fabricated. In order to quantify the effectiveness of this technique, a mix-and-match overlay study was performed using the same Ultratech 2244i and an advanced 5x reduction stepper. Overlay experiments were performed using both corrected and noncorrected reticles on the Ultratech system. An automated metrology system was used to collect overlay measurements distributed over the entire lens field area. Detailed analysis of the lens intrafield component of the overlay error using both reticles illustrates the advantages of applying reticle distortion corrections.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Warren W. Flack, Gary E. Flores, Alan D. Walther, and Manny Ferreira "Reticle correction technique to minimize lens distortion effects", Proc. SPIE 2322, 14th Annual BACUS Symposium on Photomask Technology and Management, (7 December 1994); https://doi.org/10.1117/12.195821
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reticles

Distortion

Overlay metrology

Lithography

Error analysis

Semiconducting wafers

Photomask technology

RELATED CONTENT

In-die mask registration for multi-patterning
Proceedings of SPIE (September 16 2013)
New directions in image placement metrology
Proceedings of SPIE (April 01 2011)
Absolute pattern placement metrology on wafers
Proceedings of SPIE (August 04 1993)
New distortion metrology using reticle coordinate error
Proceedings of SPIE (September 01 1998)

Back to Top