Paper
22 May 1995 Monte Carlo simulation for CD SEM calibration and algorithm development
Author Affiliations +
Abstract
For effective critical dimension metrology at geometries of 0.5 micrometers and smaller, it is essential to understand the true edge location, as represented in the SEM image profile of the feature. Total uncertainty associated with the linewidth measurement is often greater than the entire metrology error budget allocation. Capability to accurately predict (or model) the observed signal output for any type of feature is required to reduce measurement uncertainties to acceptable levels. The model, once validated, can then be used as the basis for measurement algorithms, error analysis, system calibration. In a manner analogous to the development of the optical photomask standards we investigate the capability to model, using a Monte Carlo based technique which incorporates measurement system geometries and fields, the output of an in-line, backscatter detection based, CD SEM. A comparison of line waveform profile results obtained from measurements taken of several simple resist-on-silicon test structures, with varying sidewall profiles, against simulations of the same structures is made. The line geometry for simulation input is derived using extensive analysis of in- line SEM and laboratory SEM systems for top down and crossectional measurement and an Atomic Force Microscope (AFM) for layer thickness and sidewall angle measurements. The results of these measurements is a trapezoidal line geometry for simulation input. Measurement profiles from simulation and experiment are compared and highlight the importance of; SEM operating condition (resolution/spot size) and linewidth subtleties (edge rounding at the top of the line, presence of a 'foot' or antifoot at the bottom of the line). Capability to use simulations to determine edge positions and the future work required to accomplish this are also discussed.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mark P. Davidson and Neal T. Sullivan "Monte Carlo simulation for CD SEM calibration and algorithm development", Proc. SPIE 2439, Integrated Circuit Metrology, Inspection, and Process Control IX, (22 May 1995); https://doi.org/10.1117/12.209218
Lens.org Logo
CITATIONS
Cited by 15 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Scanning electron microscopy

Standards development

Calibration

Critical dimension metrology

Data modeling

Scattering

RELATED CONTENT

Modeling metrology for calibration of OPC models
Proceedings of SPIE (March 24 2016)
Submicron calibration strategy for CD control
Proceedings of SPIE (September 13 1996)
CD control analysis of the SCALPEL-HT/alpha optics
Proceedings of SPIE (August 20 2001)
Smart data filtering for enhancement of model accuracy
Proceedings of SPIE (March 16 2009)

Back to Top