You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
17 February 1995New compression techniques for storage and transmission of 2D and 3D medical images
Two new techniques for the compression of 2D and 3D medical images are proposed in the paper. Both algorithms are based on DCT transforms and the aim is to ensure a nearly lossless image transmission and storage with a compression rate able to reduce significantly the amount of data. The first technique, used for the storage of 2D medical images (microscope, radiographic, x-ray images, ultrasonic images, computer tomograph sections) is based on the extraction of a `region of interest' in the original image. In fact, in most situations, only a limited region of the medical image is interesting for diagnosis. For compression, a direct DCT is applied on the original image, preserving a different number of coefficients inside and outside the region of interest (must be higher inside the region). The compression ratio obtained with this method depends on the size of the selected region and on the number of DCT coefficients preserved, ranging from 4 to 20. The second technique is based on the correlation existing between contiguous axial sections obtained from the CT. The 3D volume data is compressed using an original axial section and the difference images between successive sections. The advantage of this method consists in reducing the number of DCT coefficients necessary for a nearly lossless compression of the difference images. The compression ratio obtained ranges between 6 nd 10, without significant losses in the image quality.
The alert did not successfully save. Please try again later.
Aurel M. Vlaicu, Serban Lungu, Nicolae Crisan, Stelian Persa, "New compression techniques for storage and transmission of 2D and 3D medical images," Proc. SPIE 2451, Advanced Image and Video Communications and Storage Technologies, (17 February 1995); https://doi.org/10.1117/12.201220