You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
15 December 1995Spectroradiometer focal-plane design considerations: lessons learned from MISR camera testing
The EOS/MISR instrument contains nine cameras; each camera focal plane consists of four closely spaced, linear CCD arrays. Each of the four arrays is preceded by a narrow bandpass filter covering a distinct spectral region. Testing of two engineering model cameras revealed spatial and spectral optical crosstalk levels not predicted by stray light analysis. A detailed investigation of filter coating anomalies and the filter assembly/CCD geometry elucidated several mechanisms responsible for optical crosstalk. These mechanisms, as well as recommendations concerning the design of future focal planes, are presented in this paper.
The alert did not successfully save. Please try again later.
Robert P. Korechoff, David J. Diner, Daniel J. Preston, Carol J. Bruegge, "Spectroradiometer focal-plane design considerations: lessons learned from MISR camera testing," Proc. SPIE 2583, Advanced and Next-Generation Satellites, (15 December 1995); https://doi.org/10.1117/12.228556