Paper
13 September 1995 Kodak DCS200: a camera for high-accuracy measurements?
Armin Gruen, Hans-Gerd Maas, Andrea Keller
Author Affiliations +
Proceedings Volume 2598, Videometrics IV; (1995) https://doi.org/10.1117/12.220923
Event: Photonics East '95, 1995, Philadelphia, PA, United States
Abstract
The digital high-resolution stillvideo camera Kodak DCS200 has reached a high degree of popularity among photogrammetrists within a very short time. Consisting of a mirror reflex camera, a high resolution CCD sensor, A/D conversion, power supply, and data storage capacity for 50 images, it can basically be considered a comfortable, autonomous device for digital image data acquisition, especially for industrial applications and for architectural photogrammetry. First tests of the camera showed a high precision potential: 1/20-1/30 pixel in image space could be achieved in several applications, and with large self-calibrating networks relative precisions of 1:100,000 and better have been reported. To be able to make more detailed statements on the accuracy potential of the camera, a thorough accuracy test was performed at ETH Zurich by taking 150 images of a 186 target 3D testfield. Although the precision estimates of this large block were exceptionally good, strong systematic object deformations were found in comparison with theodolite-measured reference coordinates of the testfield points. The reasons for these deformations are most probably temporal instabilities of some camera parameters, which could make the use of this camera very problematic for high accuracy applications. It is argued that these instabilities are caused by the weak fixture of the CCD-chip to the camera body. In this context it is often overlooked that this camera was not developed for precise measurement applications but rather for professional photographers.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Armin Gruen, Hans-Gerd Maas, and Andrea Keller "Kodak DCS200: a camera for high-accuracy measurements?", Proc. SPIE 2598, Videometrics IV, (13 September 1995); https://doi.org/10.1117/12.220923
Lens.org Logo
CITATIONS
Cited by 13 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Sensors

Calibration

CCD cameras

3D acquisition

CCD image sensors

Data conversion

RELATED CONTENT

Spherical stereoscopic sensor for 3D color imaging
Proceedings of SPIE (June 22 2001)
New acquisition system of arbitrary ray space
Proceedings of SPIE (May 24 1999)
Fast tracking mode predictive centroiding scheme
Proceedings of SPIE (October 13 2008)
Flat-field calibration of CCD detector for long trace profiler
Proceedings of SPIE (September 20 2007)
Self calibration of a 3D object scanner based on a...
Proceedings of SPIE (December 14 1998)

Back to Top