Paper
18 September 1995 In-situ wafer contamination detection through rf-PCD Measurements
Jurgen Michel, Marcia R. Black, G. J. Norga, Kathryn A. Black, Hichem M'saad, Lionel C. Kimerling
Author Affiliations +
Abstract
Radio-frequency photoconductance decay (RF-PCD) is a contactless method of measuring minority carrier lifetime in silicon. Low detection limits and speed of measurement makes this method ideally suited for in-situ determination of silicon wafer passivation and contamination processes. Comparative measurements of copper contamination of silicon surfaces using RF- PCD and TXRF yield a detection limit of about 109 Cu/cm2. The fast detection of changes in surface defects enables the time resolved observation of surface passivation breakdown due to the exposure of the wafer to controlled atmospheres. While nitrogen does not attack the surface passivation, oxygen exposure results in immediate native oxide growth.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jurgen Michel, Marcia R. Black, G. J. Norga, Kathryn A. Black, Hichem M'saad, and Lionel C. Kimerling "In-situ wafer contamination detection through rf-PCD Measurements", Proc. SPIE 2638, Optical Characterization Techniques for High-Performance Microelectronic Device Manufacturing II, (18 September 1995); https://doi.org/10.1117/12.221203
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Semiconducting wafers

Silicon

Copper

Contamination

Oxygen

Nitrogen

Metals

Back to Top