21 May 1996 Multiparameter CD measurements using scatterometry
Christopher J. Raymond, Michael R. Murnane, Steven L. Prins, S. Sohail H. Naqvi, John Robert McNeil, Jimmy W. Hosch
Author Affiliations +
Abstract
Scatterometry, the characterization of periodic structures via diffracted light analysis, is shown to be a versatile metrology technique applicable to several processes involved in microlithography. Unlike contemporary inspection technologies, such as scanning force microscopy (SFM) and scanning electron microscopy (SEM), scatterometry is rapid, non- destructive, inexpensive and has the potential for use in-situ. Furthermore, the flexibility of the technique allows it to be used for a number of different process measurements. In the production of a sub-micron microelectronic device, a typical series of process steps could involve the deposition of a poly-Si layer on oxide, followed by the application of an anti- reflection coating (ARC) and resist layer. Thus in total there are four parameters which will ultimately affect the overall quality of subsequent processing: the linewidth of the resist, the resist height, and the thicknesses of the ARC and poly-Si. We have demonstrated that the scatterometer measurement technique is robust to changes in the thickness of underlying films. Indeed, there is sufficient information in one signature to determine four parameters at once, even when the linewidth dimensions are as small as 0.16 micrometer and the poly-Si thickness is on the order of 2500 angstrom. Results from determining these dimensions on several wafers show excellent agreement between the scatterometry measurements and measurements made with other metrology instruments (top down and cross-section SEM, and ellipsometer). For example, the average bias between nine scatterometry and cross-section SEM measurements on nominal 0.35 micrometer lines is minus 1.7 nm; for 0.25 micrometer lines, the average difference is minus 7.3 nm. In addition, results from measuring the sidewall angle (a fifth parameter) from these same scatter signatures indicate that the resist profiles at optimum focus and exposure are near-vertical. Finally, the dynamic repeatability of this technique is shown to be excellent for all of the parameters measured (linewidth, resist height, ARC thickness and poly thickness). For example, the 3(sigma) repeatability of measurements on a 207 nm linewidth is 0.75 nm and the 3 sigma repeatability for measurements on a 311 nm linewidth is 1.08 nm.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christopher J. Raymond, Michael R. Murnane, Steven L. Prins, S. Sohail H. Naqvi, John Robert McNeil, and Jimmy W. Hosch "Multiparameter CD measurements using scatterometry", Proc. SPIE 2725, Metrology, Inspection, and Process Control for Microlithography X, (21 May 1996); https://doi.org/10.1117/12.240121
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scatterometry

Semiconducting wafers

Scanning electron microscopy

Scatter measurement

Metrology

Ellipsometry

Diffraction

Back to Top