Paper
14 June 1996 Concealed explosive detection on personnel using a wideband holographic millimeter-wave imaging system
David M. Sheen, Douglas L. McMakin, H. Dale Collins, Thomas E. Hall, Ronald H. Severtsen
Author Affiliations +
Abstract
A novel wideband millimeter-wave imaging system is presently being developed at Pacific Northwest National Laboratory (PNNL) that will allow rapid inspection of personnel for concealed explosives, handguns, or other threats. Millimeter-wavelength electromagnetic waves are effective for this application since they readily penetrate common clothing materials, while being partially reflected from the person under surveillance as well as any concealed items. To form an image rapidly, a linear array of 128 antennas is used to electronically scan over a horizontal aperture of 0.75 meters, while the linear array is mechanically swept over a vertical aperture of 2 meters. At each point over this 2-D aperture, coherent wideband data reflected from the target is gathered using wide-beamwidth antennas. The data is recorded coherently, and reconstructed (focused) using an efficient image reconstruction algorithm developed at PNNL. This algorithm works in the near-field of both the target and the scanned aperture and preserves the diffraction limited resolution of less than one-wavelength. The wide frequency bandwidth is used to provide depth resolution, which allows the image to be fully focused over a wide range of depths, resulting in a full 3-D image. This is not possible in a normal optical (or quasi-optical) imaging system. This system has been extensively tested using concealed metal and plastic weapons, and has recently been tested using real plastic explosives (C-4 and RDX) and simulated liquid explosives concealed on personnel. Millimeter-waves do not penetrate the human body, so it is necessary to view the subject from several angles in order to fully inspect for concealed weapons. Full animations containing 36 - 72 frames recorded from subjects rotated by 5 - 10 degrees, have been found to be extremely useful for rapid, effective inspection of personnel.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David M. Sheen, Douglas L. McMakin, H. Dale Collins, Thomas E. Hall, and Ronald H. Severtsen "Concealed explosive detection on personnel using a wideband holographic millimeter-wave imaging system", Proc. SPIE 2755, Signal Processing, Sensor Fusion, and Target Recognition V, (14 June 1996); https://doi.org/10.1117/12.243191
Lens.org Logo
CITATIONS
Cited by 46 scholarly publications and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Imaging systems

Explosives

Millimeter wave imaging

Reconstruction algorithms

Weapons

Holography

3D image processing

Back to Top