21 October 1996 Diode laser MIR-DFG spectrometer for trace gas detection
Author Affiliations +
Abstract
Two cw-single mode diode-lasers with powers of 30 and 50 mW at the center wavelengths 682 and 791 nm are applied as signal and pump sources for difference frequency generation (DFG) in an AgGaS2 crystal with a length of 30 mm. For 90 degree type I phase matching tunable mid-infrared laser radiation is obtained in the spectral range between 4.9 and 5.1 micrometers , while the DFG-output power is 0.2 (mu) W. The performance of this diode-laser MIR-DFG spectrometer is shown as the absorption of CO for the P(28) rotational line around 2023 cm-1 is probed in a cell and on-line in the exhaust of an engine.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ulrike Willer, Torsten Blanke, and Wolfgang Schade "Diode laser MIR-DFG spectrometer for trace gas detection", Proc. SPIE 2834, Application of Tunable Diode and Other Infrared Sources for Atmospheric Studies and Industrial Process Monitoring, (21 October 1996); https://doi.org/10.1117/12.255333