27 February 1997 Simulations of neutron and proton detection for a 4π plastic scintillator detector
Tomislav Petkovic, N. Simicevic, R. Trezeciak, H. Ullrich
Author Affiliations +
Proceedings Volume 2867, International Conference Neutrons in Research and Industry; (1997) https://doi.org/10.1117/12.267856
Event: Fifth International Conference on Applications of Nuclear Techniques: Neutrons in Research and Industry, 1996, Crete, Greece
Abstract
Neutron detection efficiencies for a 4 (pi) plastic scintillator detector were calculated with the Monte Carlo code of Cecil et al for various threshold of 2.5, 5, 7.5, 10 and 20 MeVee, assuming an isotropic distribution of neutrons emerging form the center of the target. A good agreement between the data obtained from the reaction (pi) +4He yields pppn with 120 MeV pions and efficiency calculations has been found. Proton reaction losses for 15, 20 and 35 cm thick plastic detectors were calculated using the GEANT code for proton energies up to 150 MeV. Reaction losses were extracted from the simulated spectra. Our correction curve for proton reaction losses gives slightly higher values than the data of Measday and Serre and the calculation of Janni.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tomislav Petkovic, N. Simicevic, R. Trezeciak, and H. Ullrich "Simulations of neutron and proton detection for a 4π plastic scintillator detector", Proc. SPIE 2867, International Conference Neutrons in Research and Industry, (27 February 1997); https://doi.org/10.1117/12.267856
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scintillators

Sensors

Monte Carlo methods

Carbon

Computer simulations

Signal attenuation

Absorption

RELATED CONTENT


Back to Top