Paper
27 December 1996 Evaluation of a new photomask CD metrology tool
Leonard F. Dubuque, Nicholas G. Doe, Patrick St. Cin
Author Affiliations +
Abstract
In the integrated circuit (IC) photomask industry today, dense IC patterns, sub-micron critical dimensions (CD), and narrow tolerances for 64 M technologies and beyond are driving increased demands to minimize and characterize all components of photomask CD variation. This places strict requirements on photomask CD metrology in order to accurately characterize the mask CD error distribution. According to the gauge-maker's rule, measurement error must not exceed 30% of the tolerance on the product dimension measured or the gauge is not considered capable. The traditional single point repeatability tests are a poor measure of overall measurement system error in a dynamic, leading-edge technology environment. In such an environment, measurements may be taken at different points in the field- of-view due to stage in-accuracy, pattern recognition requirements, and throughput considerations. With this in mind, a set of experiments were designed to characterize thoroughly the metrology tool's repeatability and systematic error. Original experiments provided inconclusive results and had to be extended to obtain a full characterization of the system. Tests demonstrated a performance of better than 15 nm total CD error. Using this test as a tool for further development, the authors were able to determine the effects of various system components and measure the improvement with changes in optics, electronics, and software. Optimization of the optical path, electronics, and system software has yielded a new instrument with a total system error of better than 8 nm. Good collaboration between the photomask manufacturer and the equipment supplier has led to a realistic test of system performance and an improved CD measurement instrument.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Leonard F. Dubuque, Nicholas G. Doe, and Patrick St. Cin "Evaluation of a new photomask CD metrology tool", Proc. SPIE 2884, 16th Annual BACUS Symposium on Photomask Technology and Management, (27 December 1996); https://doi.org/10.1117/12.262804
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photomasks

Critical dimension metrology

Metrology

Tolerancing

Electronics

Environmental sensing

Optics manufacturing

RELATED CONTENT

The AIMS tool: its potentials, applications, and issues
Proceedings of SPIE (December 18 1998)
Using the Leitz LMS 2000 for monitoring and improvement of...
Proceedings of SPIE (November 03 1994)
Metrology on phase-shift masks
Proceedings of SPIE (June 01 1992)
Automatic bake plate calibration
Proceedings of SPIE (December 06 2004)

Back to Top