Abstract
The compound-tomography imaging spectrometer (CTIS) captures a scene's spatial and spectral information without any type of scanning. This capability enables a variety of applications that require spectral imaging of transient events. In this work, we demonstrate a flexible CTIS calibration techniques that allows multiple scene resolutions to be reconstructed from a single detector frame. The technique combines measurements with simulations to determine the transfer matrix of the system. Reconstructions of an experimental scene are performed to demonstrate the flexibility of the approach.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel W. Wilson, Paul D. Maker, and Richard E. Muller "Reconstructions of computed-tomography imaging spectrometer image cubes using calculated system matrices", Proc. SPIE 3118, Imaging Spectrometry III, (31 October 1997); https://doi.org/10.1117/12.283827