Paper
19 November 1998 Spectral features in the AXAF HETGS effective area using high-signal-continuum tests
Herman L. Marshall, Daniel Dewey, Norbert S. Schulz, Kathryn A. Flanagan
Author Affiliations +
Abstract
In order to probe for small scale spectral features of the High Energy Transmission Grating Spectrometer (HETGS) and the low energy transmission grating, we performed test at the AXAF X-Ray Calibration Facility (XRCF) using a very bright continuum source. THE Electron Impact Point Source (EIPS) was used with the Cu anode and operated at high voltage and low current in order to provide a bright continuum at high energies. The AXAF CCD Imaging Spectrometer Spectroscopy detector (ACIS-S) was used to discriminate orders and to provide high throughput when operate in continuous clocking mode. Many spectral features are observed but most of them are emission lines attributable to the source spectrum. We find that the current models for the HETG efficiency, the LETG efficiency and the AXAF High Resolution Mirror Assembly effective area predict very well the observed fine structure near the Au and Ir M edges where the models are most complex. Edges in the detector filter and quantum efficiency (QE) curves are somewhat more sharply defined in the data than in the current modes. By comparing the positive and negative dispersion regions, we find no significant efficiency asymmetry attributable to the gratings and we can further infer that the QEs of the ACIS-S frontside illuminated (FI) chips are consistent to +/- 10 percent. On the other hand, we derive the ratio of the QE for the backside illuminated (BI) chips relative to that of the FI chips and show that it deviates for the expected ratio. This deviation may result from grade differences due to operation in CC mode while most calibration data are obtained in timed event mode.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Herman L. Marshall, Daniel Dewey, Norbert S. Schulz, and Kathryn A. Flanagan "Spectral features in the AXAF HETGS effective area using high-signal-continuum tests", Proc. SPIE 3444, X-Ray Optics, Instruments, and Missions, (19 November 1998); https://doi.org/10.1117/12.331280
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Quantum efficiency

Charge-coupled devices

Data modeling

Sensors

Spectroscopy

Bismuth

Calibration

RELATED CONTENT

X-ray CCD calibration for the AXAF CCD Imaging Spectrometer
Proceedings of SPIE (October 31 1996)
The VIMOS upgrade programme
Proceedings of SPIE (September 24 2012)
Absolute effective areas of the HETGS
Proceedings of SPIE (November 19 1998)

Back to Top