You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
3 June 1999Optical and electrochemical diffusion-based detection of analytes in complex samples using microfabricated flow structures (T-Sensors)
T-Sensors have been demonstrated to allow both absorption- and fluorescence-based detection of analytes directly in complex samples such as whole blood and contaminated environmental samples, without prior separation of blood cells or other soluble and insoluble components. In this paper, we present the implementation of electrochemical detection methods in T- Sensors, as well as their optical validation. Microelectrodes integrated with etched microfluidic flow channels allow traditional electroanalytical techniques to be performed on microliter and smaller volumes and also enable new detection techniques which are based upon the interaction between the microelectrodes and the diffusional mixing that occurs between flow lamina at low Reynolds numbers. Conductivity versus mixing measurements, anodic stripping voltammetry, and isolation of microelectrodes by sheath flow are demonstrated for an experimental device. In a T-Sensor, a sample solution, a receptor solution, and, optionally, a reference solution (a known analyte standard) are introduced in a common channel (T- SensorTM), and laminarly flow next to each other until the exit the structure. Smaller particles such as ions or small proteins diffuse rapidly across the fluid boundaries, whereas larger molecules diffuse more slowly. Large particles show no significant diffusion within the time the two flow streams are in contact. Two interface zones are formed between the fluid layers. The ratio of a property (e.g., fluorescence intensity, stripping voltammetry signal) of the two interface zones is a function of the concentration of the analyte, and is largely free of cross-sensitivities to other sample components and instrument parameters.
The alert did not successfully save. Please try again later.
Bernhard H. Weigl, Robert B. Darling, Paul Yager, Jennah Kriebel, Kelly Mayes, "Optical and electrochemical diffusion-based detection of analytes in complex samples using microfabricated flow structures (T-Sensors)," Proc. SPIE 3606, Micro- and Nanofabricated Structures and Devices for Biomedical Environmental Applications II, (3 June 1999); https://doi.org/10.1117/12.350048