You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
24 May 1999Effects of radiation dose and display contrast on low-contrast phantom image visibility
Computed radiography (CR) radiographs were generated of a low contrast phantom with 5 mm diameter disks. The radiation exposure incident on the imaging plate was varied from approximately 0.1 mR to approximately 10 mR, with the phantom images printed to film using a range of display contrast settings. Changing the radiation exposure by two orders of magnitude had only a modest effect on disk detection performance (approximately 20%), and much less than predicted by signal detection theory for the perception of noise limited objects. For images generated at approximately 1 and approximately 10 mR, increasing the display contrast markedly improved the disk detection performance (approximately 50%). There was approximate agreement between the experimental data and the corresponding theoretical predictions for the detection of contrast limited objects. For the contrast detail phantom employed in this study, disk detection was primarily contrast limited, with image noise being relatively unimportant. Lesion detection with an anthropomorphic phantom containing a structured background wold be unlikely to change this conclusion, since noise is expected to be most important for low contrast objects viewed against a uniform background. Contrast enhancement, as opposed to increasing radiation exposure, is therefore the method of choice for improving the detection of 5 mm diameter sized low contrast lesions in CR images.
The alert did not successfully save. Please try again later.
Charles C. Chamberlain, Walter Huda, Andrij R. Wojtowycz, "Effects of radiation dose and display contrast on low-contrast phantom image visibility," Proc. SPIE 3663, Medical Imaging 1999: Image Perception and Performance, (24 May 1999); https://doi.org/10.1117/12.349661