Paper
24 September 1999 EO-1 Advanced Land Imager calibration and performance overview
Author Affiliations +
Abstract
The pre-launch measurements and test required for calibration and characterization of the advanced land imager (ALI), which will be flown on NASA's EO-1 mission, have been completed. The instrument level performance testing was conducted at MIT Lincoln Laboratory with the ALI in an operational environment. The overall calibration strategy, which includes both pre-launch and post-launch components, will be described in this paper. The fundamental sensor calibration data comprise five measurement categories: angular position in object space for each pixel; normalized spectral response functions; response coefficients; zero signal offsets; and modulation transfer functions. Performance and characterization test include measurements of noise, SNR, linearity, repeatability, image artifacts, stray light rejection, and cross-talk. An overview of the facilities, equipment, tests and results is presented here.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Donald E. Lencioni, David R. Hearn, Jeffrey A. Mendenhall, and William E. Bicknell "EO-1 Advanced Land Imager calibration and performance overview", Proc. SPIE 3750, Earth Observing Systems IV, (24 September 1999); https://doi.org/10.1117/12.363502
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Sensors

Signal to noise ratio

Collimators

Earth observing sensors

Imaging systems

Landsat

RELATED CONTENT

Landsat-8 TIRS thermal radiometric calibration status
Proceedings of SPIE (September 05 2017)
On orbit test results from the EO 1 Advanced Land...
Proceedings of SPIE (January 18 2002)
Design and performance of the EO-1 Advanced Land Imager
Proceedings of SPIE (December 28 1999)
Summary of the operational land imager focal plane array for...
Proceedings of SPIE (September 16 2011)
EO-1 Advanced Land Imager in-flight calibration
Proceedings of SPIE (October 03 1998)

Back to Top