Paper
22 October 1999 Calibration of the X-ray CCD camera (XIS) for the ASTRO-E in the soft-x-ray band
Haruyoshi Katayama, Makoto Shouho, Takayoshi Kohmura, Kazunori Katayama, Motoari Ohta, Hiroshi Tsunemi, Shunji Kitamoto, Kiyoshi Hayashida, Emi Miyata, Kumi Yoshita, Katsuji Koyama, George R. Ricker Jr., Mark W. Bautz, Richard F. Foster, Steven E. Kissel, John P. Doty
Author Affiliations +
Abstract
The ASTRO-E X-ray Imaging Spectrometers (XISs) consists of four sets of X-ray CCD camera for the ASTRO-E mission. The XISs have been calibrated at Osaka University, Kyoto University, ISAS and MIT. The calibration experiment at Osaka focuses on the soft x-ray response of the XIS. The calibration of the XIS flight model has been performed since August 1998. We measured the signal-pulse height, the energy resolution and the quantum efficiency of the XIS as a function of energy, all of which are essential to construct the response function of the XIS. The detailed shape of the pulse-height-distribution are also investigated. We also constructed a numerical simulator of the XIS, which tracks the physical process in the CCD so as to reproduce the measured data. With a help of this simulator, we propose a model of the pulse-height-distribution of the XIS for single energy incident x-rays. The model consists of four components; two Gaussians, a constant, plus a triangle-shape component.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Haruyoshi Katayama, Makoto Shouho, Takayoshi Kohmura, Kazunori Katayama, Motoari Ohta, Hiroshi Tsunemi, Shunji Kitamoto, Kiyoshi Hayashida, Emi Miyata, Kumi Yoshita, Katsuji Koyama, George R. Ricker Jr., Mark W. Bautz, Richard F. Foster, Steven E. Kissel, and John P. Doty "Calibration of the X-ray CCD camera (XIS) for the ASTRO-E in the soft-x-ray band", Proc. SPIE 3765, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy X, (22 October 1999); https://doi.org/10.1117/12.366554
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Charge-coupled devices

Calibration

Spectrometers

CCD cameras

Absorption

Computer simulations

RELATED CONTENT

The Soft X ray Imager (SXI) for the ASTRO H...
Proceedings of SPIE (September 18 2015)
Soft x ray response of the prototype CCD camera (XIS)...
Proceedings of SPIE (November 10 1998)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)

Back to Top